Schneider Electric ATV320U22M2C Variable Frequency Drive
Controls single-phase 240 V input to three-phase output up to 11 A and 599 Hz for 3 hp motors
- Product typeMotors
- Precise motor speed control from .1 to 599 Hz output range
- Single-phase 240 V AC input simplifies installation in standard facilities
- Delivers three-phase 240 V AC output up to 3 hp for versatile motor driving
- Rated 11 A maximum output current handles demanding industrial loads
- NEMA 1 enclosure protects drive in typical indoor environments
Variable Frequency Drive 240 V AC
The Schneider Electric ATV320U22M2C is a variable frequency drive designed for single-phase 240 V AC input at 50 or 60 Hz. It delivers three-phase 240 V AC output up to 3 hp and 11 A for motor control applications. The NEMA 1 enclosure suits indoor industrial environments.
Sustained Load Behaviour
The drive maintains continuous output across a frequency range of 0.1 to 599 Hz for speed regulation. Three-phase output supports steady torque delivery to the connected motor. Thermal management is handled within the rated enclosure for ongoing operation.
Interface Practical Limits
Single-phase 240 V AC input restricts use to compatible supply networks. Output frequency tops out at 599 Hz for high-speed motor requirements. Maximum output current of 11 A defines the motor size the drive can serve.
How it compares
Measured against everything we stock in Wire, Cable & Wiring Supplies, at today’s prices. Recalculated every night.
- Price $506.99
- Pricier than about 91% of the 1,610 comparable items (median $25.99).
Specifications
| Product | |
|---|---|
| Brand name | SCHNEIDER ELECTRIC |
| Product type | Motors |
Questions about this item
How much heat does the 11 A output current generate during continuous operation?
The drive delivers up to 11 A at 240 V AC three-phase output; heat dissipation scales with load, so ensure the NEMA 1 enclosure has adequate ventilation for all-day running.
What supply wiring and protection does the 240 V AC single-phase input require?
Feed the drive from a 240 V AC single-phase source at 50 or 60 Hz with a suitably rated circuit breaker and conductors sized for the 3 hp maximum output power.
Will the 0.1 to 599 Hz output range drive an older 50 Hz motor without modification?
Yes, the variable frequency drive can run a legacy 50 Hz motor across the full 0.1 to 599 Hz range, letting you match the original speed or adjust it as needed.
More in Wire, Cable & Wiring Supplies
Similar items
Allen-Bradley 1756-OB16E ControlLogix 16 Point D/O Module
- Power Supply Cord
PREMIERE RACEWAY PRODUCTS Wire Hider FRA-33414 1-1/2" White Right Angle Self Adhesive
Zoro Select 3001829 Bronze Screen 60 in W 50 ft L 0.011 in Wire Dia
- Wire Fabric
PREMIERE RACEWAY PRODUCTS 53414 1-1/2" Outside Corner White Self Adhesive
Tyrap TY29M Industrial Wire Cable Tie 30.3 in 120 lb
- Cable Management &…