SAMSUNG Atlas Sound AT-100 100W Commercial Attenuator video accessory
- Hard Wire Dimmer
- Black
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Overload relay rated 55 to 70 A, Class 10, three-pole, 690 V for LC1D65 to LC1D80 contactors
The Schneider Electric LRD3361 is a thermal overload relay designed to protect three-phase motors from excessive current. It mounts directly onto LC1D65 through LC1D80 contactors and covers a setting range of 55 to 70 amperes. The device operates at up to 690 volts and uses a Class 10 trip characteristic. Manual reset is required after a trip event.
This relay suits panels where a 55 to 70 ampere motor starter needs overload protection with a Class 10 response. It fits only the LC1D65 to LC1D80 contactor frame sizes, so installers using smaller or larger contactors must select a different relay. Applications requiring automatic or remote reset should choose another model because this unit resets manually.
The adjustable current range of 55 to 70 amperes combined with a Class 10 trip class is the specification that determines whether this relay matches the motor full-load current and the required acceleration time. Verify the motor nameplate current falls inside this window and that a Class 10 trip curve suits the load before selecting the LRD3361.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Schneider Electric |
| Model name | LRD3361 |
| Product type | 3 in Harsh Environment, Hook-and-Loop Closure |
The relay is rated for a 55 to 70A current range and Class 10 trip, so sustained operation at the upper limit will produce heat consistent with that load.
It is designed for use with Schneider Electric LC1D65 to LC1D80 series contactors.
Yes, the relay is specified for the LC1D65 to LC1D80 range, so it will work with that contactor.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?