SIEMENS SITOP PSU100C 12V 24W DIN Rail Power Supply
DIN-rail switching supply converts 85 to 264V AC or 110 to 300V DC to 12V DC at 24W with 2A continuous and 33A peak output
- Product typePower Quality & Distribution
- Wide input range 85 to 264V AC and 110 to 300V DC
- Compact DIN rail design 30mm wide fits tight cabinets
- Reliable 12V 2A output with 33A peak for start-up surges
- Green LED status indicator shows OK at a glance
- Operates from -20°C to 70°C for harsh environments
Compact DIN rail supply for control panels
The SIEMENS SITOP PSU100C delivers a regulated 12 V DC output at 24 W from a 100 to 230 V AC or 110 to 300 V DC input. It fits on a standard DIN rail inside enclosures rated to NEMA 1 and IP20, serving automation and building-system loads that require a stable low-voltage rail.
Convection cooled with green LED status
Natural convection handles the 24 W load without a fan, so acoustic noise is absent in normal operation. The unit tolerates an ambient range of -20 to 70 °C and maintains output with a hold-up time greater than 20 ms; ripple and noise measure 200 mV peak-to-peak and 40 mV RMS. Peak current capability reaches 33 A for brief inrush events.
Plastic housing and single-phase wiring simplify
The 30 mm wide plastic case leaves dense rail space for adjacent modules. A green OK LED gives immediate visual confirmation of output presence. Single-phase 50 to 60 Hz supply wiring keeps termination straightforward for panel builders.
How it compares
Measured against everything we stock in Electrical Enclosures & Cabinets, at today’s prices. Recalculated every night.
- Price $100.99
- Pricier than about 75% of the 1,411 comparable items (median $39.99).
Specifications
| Product | |
|---|---|
| Brand name | SIEMENS |
| Product type | Power Quality & Distribution |
Questions about this item
How do I mount the 30 mm wide DIN-rail unit and what step is often missed?
Clip the plastic case onto a standard DIN rail, then verify the green LED OK signal lights to confirm 12 V DC output is present.
Which part will need replacement first during continuous operation?
The internal electrolytic capacitors age fastest; plan replacement after several years at the upper end of the -20 to 70 °C range.
What limit appears first when the supply runs at 24 W continuously?
Output ripple reaches the specified 200 mV peak-to-peak before thermal protection engages at 70 °C.
More in Electrical Enclosures & Cabinets
Similar items
HOFFMAN A806LP NEMA 12/13 8x6x3.5 in wall mount enclosure
- Electrical Boxes &…
HOFFMAN A606CHQR Quick Release Latch Electrical Box 6 in H 4 in
- Electrical Enclosur…