We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Solid 18 AWG copper building wire, 500 ft green TFFN on a spool, 600 V vinyl insulation, .08 in. outside diameter
This 18 AWG TFFN building wire uses a solid copper conductor with green vinyl insulation rated for 600 V. The 500 ft spool suits electricians and contractors pulling single-conductor circuits through conduit systems. Nominal outside diameter is .08 in for standard conduit fill calculations.
The solid conductor resists deformation when pushed through long or bent conduit runs. Green insulation identifies the conductor for grounding or specific circuit coding per electrical standards. Spool packaging keeps the wire tangle-free during installation and allows smooth pay-out from a reel stand.
This TFFN wire is rated for 600 V maximum and intended for installation inside raceway or conduit. It is not rated for direct burial, exposed runs or wet locations without additional protection. Solid 18 AWG gauge limits ampacity, so it cannot serve high-current branch circuits requiring larger conductors.
Measured against everything we stock in Electrical Conduit & Fittings, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SOUTHWIRE |
| Product type | Wire & Cable |
Solid 18 AWG copper conductors in TFFN wire do not require re-torquing; the wire is rated for continuous service at 600 V and is replaced only if insulation is damaged or the conductor is severed.
The 600 V insulation rating and the ampacity of 18 AWG copper set the thermal limit; sustained current above the NEC ampacity for this gauge will cause insulation degradation before any other failure mode.
Heat rise depends on the actual load current and conduit fill; at the 18 AWG ampacity the vinyl insulation operates within its 600 V temperature rating, and the 0.08 in outside diameter allows normal convection cooling.
More in Electrical Conduit & Fittings
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?