We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
18 AWG stranded TFFN fixture wire with PVC insulation and nylon jacket, 600 V rating, on a 500 ft spool
Southwire 27022301 is a single-conductor TFFN fixture wire built for installation in conduit systems. The 18 AWG stranded copper conductor carries a 600 V AC rating and is insulated with PVC under a white nylon jacket measuring 0.09 in nominal outside diameter. Supplied on a 500 ft spool, it suits commercial and residential lighting circuits pulled through raceway.
Stranded 16-strand construction makes this wire far easier to pull through bends and long conduit runs than solid alternatives. The nylon jacket resists abrasion during installation, reducing insulation damage that would require re-pulling. The upgrade is worth it whenever conduit fill, frequent bends or long distances make solid wire difficult to handle.
TFFN insulation is not rated for direct burial, exposed outdoor use or installation without a raceway. The 600 V rating applies only when the wire remains inside listed conduit or tubing. Installers must follow applicable code for conductor fill, temperature derating and overcurrent protection; the wire itself provides no additional circuit protection.
Measured against everything we stock in Electrical Conduit & Fittings, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SOUTHWIRE |
| Color and finish | White |
| Product type | Wire & Cable Staples |
Choose conduit with an inside diameter large enough for the 0.09 in wire OD plus NEC fill limits; 1/2 in EMT is commonly used for single 18 AWG runs.
Use wire-pulling lubricant, feed from the spool straight into the conduit, and avoid sharp bends that exceed the minimum bend radius for 18 AWG stranded conductors.
Inspect the jacket for cuts, abrasion, or discoloration after any pulling job and before energising; replace any length where the nylon is breached or the PVC insulation is exposed.
More in Electrical Conduit & Fittings
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?