SQUARE D 9013FH Pressure Switch 95-125 PSI 4 Port Unload
Controls air-compressor pressure between 95 and 125 psi with a 30 psi differential and four 1/4-inch ports
- Product typeLight Switch
- Factory-set 95–125 psi cut-in/cut-out for consistent compressor cycling
- 30 psi differential keeps motor starts smooth and predictable
- Four ¼ in FNPS ports plus unloader valve simplify plumbing
- DPST contacts rated 2 hp at 120 V and 5 hp at 240 V three-phase
- NEMA 1 enclosure suits indoor workshop environments
Pressure Switch for Air Compressors
This Square D 9013FH pressure switch controls air compressors with a factory-set cut-in of 95 psi and cut-out of 125 psi. It handles single-phase motors up to 2 hp at 120 V or 3 hp at 240 V, and three-phase motors up to 5 hp at 240 V or 1 hp at 480 V. The unit is rated NEMA 1 for indoor use.
Four-Port Installation with Unloader
The switch provides four 1/4 in FNPS ports and includes a built-in unloader valve for automatic pressure release. Wiring uses a DPST contact form with standard action. No pilot or additional control components are supplied, so installers must provide their own fittings and conduit.
Pressure Range and Differential Limits
The adjustable operating range spans 40 to 150 psi with a fixed 30 psi differential between cut-in and cut-out. Settings outside this window are not supported. The NEMA 1 enclosure does not protect against water, dust or corrosive atmospheres, limiting use to clean, dry indoor locations.
How it compares
Measured against everything we stock in Electrical Switches & Dimmers, at today’s prices. Recalculated every night.
- Price $50.99
- Pricier than about 58% of the 791 comparable items (median $39.99).
Specifications
| Product | |
|---|---|
| Brand name | Square D |
| Product type | Light Switch |
Questions about this item
How can I verify the 9013FH pressure switch is operating correctly after installation?
Watch the compressor cycle: it should start at 95 psi and stop at 125 psi, giving a 30 psi differential, and the unloader valve must vent air briefly each time the motor stops.
What components are included with the 9013FH switch and what must I supply separately?
The switch body with four 1/4 in FNPT ports and integral unloader valve is included; you must provide 1/4 in compression fittings, tubing, wiring rated for the motor voltage, and a suitable NEMA 1 enclosure if not already mounted.
Which voltage and phase rating should I select for a 2 hp single-phase motor?
Choose the 120 V single-phase rating, which supports up to 2 hp; for 240 V single-phase the limit is 3 hp, and three-phase ratings are 5 hp at 240 V or 1 hp at 480 V.
More in Electrical Switches & Dimmers
Similar items
Schneider Electric 9001KR3RH6 30 mm Red Push Button
- Red
- Light Switch
Leviton Manufacturing Co. 052-10097-008 pull chain switch
Schneider Electric 9001KR3BH5 30mm Black Push Button
- Black
- Light Switch
Schneider Electric 9001KR1BH5 30 mm Momentary Push Button Operator, 1NO, Black
- Black