SQUARE D 9013FS Pressure Switch 40-60PSI DPST 10A
Controls water-pump pressure at 40-60 psi with a DPST 10 A contact rated for up to 2 hp at 240 V
- Product typeLight Switch
- Color and finishBlack
- Controls water-pump pressure between 40 and 60 psi
- DPST contacts handle up to 10 A switching
- Operates reliably from -22 to 257 °F
- NEMA 1 rating suits indoor installations
- Adjustable differential of 15 to 30 psi
SQUARE D 9013FS Pressure Switch
The SQUARE D 9013FS is a pressure switch designed for water pump control in residential and light commercial systems. It operates with a factory-set cut-in of 40 psi and cut-out of 60 psi. The unit features a DPST contact form rated at 10 amperes and a single 1/4 inch FNPS port. It suits installers needing a direct replacement for standard pump pressure regulation.
Thermals noise and power draw
The switch contains no active cooling components and generates no audible noise during operation. Power consumption is limited to the control circuit of the connected pump motor. Electrical ratings cover single-phase loads up to 1.5 horsepower at 120 volts and 2 horsepower at 240 volts. Three-phase ratings reach 3 horsepower at 240 volts and 1 horsepower at 480 volts.
Bundled accessories and software
The product ships as a standalone switch with no bundled accessories, software or unloader valve. The differential adjustment range spans 15 to 30 psi within an overall pressure range of 5 to 65 psi. NEMA 1 enclosure rating suits indoor installations. Operating temperature range extends from -22 degrees to 257 degrees Fahrenheit.
How it compares
Measured against everything we stock in Electrical Switches & Dimmers, at today’s prices. Recalculated every night.
- Price $24.99
- Cheaper than about 72% of the 791 comparable items (median $39.99).
Specifications
| Product | |
|---|---|
| Brand name | Square D |
| Product type | Light Switch |
| Color and finish | Black |
Questions about this item
How do I wire the DPST contacts on this 9013FS pressure switch for a 120 V pump?
Connect the two hot leads to the DPST terminals so both lines break at 40 psi cut-in and 60 psi cut-out; the switch is rated 1 1/2 hp at 120 V single phase and 10 A maximum.
What part will need replacement first on this 9013FS switch?
The internal diaphragm and contacts wear from repeated cycling between 40 and 60 psi; the differential can be adjusted 15 to 30 psi to reduce cycling frequency and extend service life.
What pressure or temperature limit stops this 9013FS switch from working continuously?
The NEMA 1 enclosure and 257 °F upper temperature rating are the first limits; sustained operation above that temperature or beyond the 65 psi maximum range will cause failure.
More in Electrical Switches & Dimmers
Similar items
Hubbell Incorporated HBL8300HRED Duplex Receptacle 20A 125V Hospital Grade Red
- Rouge
- Wiring Devices
Leviton Manufacturing Co. 052-10097-008 pull chain switch
Hubbell HBL8200GY 15 A Straight Blade Receptacle Gray
- Gray
- Wiring Devices
Hubbell Incorporated HBL1222W toggle switch 2-pole 20 A 120/277 V white
- White
- White