SUPCO CR100X370R HVAC Control 100 MFD 370 VAC
A round run capacitor rated 100 MFD at 370 VAC for air-conditioning and refrigeration compressors, furnace blowers and condenser fan motors, with a drawn steel case measuring 2.375" x 4.9375".
- Rated voltage370
- Number of items1
- 100 MFD capacitance supports reliable compressor starts
- 370 VAC rating matches standard HVAC system voltage
- UL and VDE agency listings confirm safety compliance
- 40 °F to 185 °F operating range suits extreme conditions
- Quad blade quick-connect terminals speed up installation
Round Run Capacitor 100 MFD 370 VAC
The Supco CR100X370R is a round motor run capacitor rated at 100 microfarads and 370 volts AC. It uses a drawn steel case measuring 2.375 by 4.9375 inches and carries UL and VDE approvals. Quad blade quick-connect terminals simplify wiring during installation.
HVAC motor replacements and compressor circuits
Technicians servicing air conditioning compressors, refrigeration compressors, furnace blower motors or condenser fan motors will find this part a direct replacement for Packard PRC100 and Mars 12916. It is not suited for applications requiring a different capacitance value, a higher voltage rating or a non-round case style.
100 microfarad capacitance rating
The single specification that determines fit is the 100 MFD rating with a plus or minus five percent tolerance. A system designed for a different microfarad value will not operate correctly with this capacitor.
How it compares
Measured against everything we stock in Heating & Cooling Controllers, at today’s prices. Recalculated every night.
- Price $12.99
- Cheaper than about 84% of the 1,762 comparable items (median $45.99).
Specifications
| Product | |
|---|---|
| Brand name | Supco |
| Model name | CR100 × 370R |
| Power | |
| Rated voltage | 370 |
| In the box | |
| Number of items | 1 |
Questions about this item
How often will the 100 MFD capacitor need replacement in continuous HVAC service?
Run capacitors like this CR100X370R are designed for years of duty; replace when capacitance drifts outside the ±5 % tolerance or the internal interrupter disconnects the element.
What is the first limit reached when the capacitor runs at full load for hours?
The operating ceiling is 185 °F (85 °C) case temperature; exceeding it triggers the physical interrupter and ends the run cycle.
How much heat does the 2.375" x 4.9375" steel case dissipate during all-day operation?
The drawn steel case and biodegradable oil are rated for continuous 370 VAC duty up to 185 °F; no forced-air cooling is specified by the manufacturer.
More in Heating & Cooling Controllers