Tripp Lite PDUB201U PDU Hot Swap Manual Bypass 15A 6 5-20R 2 5-20P Inputs
Hot-swap PDU with manual bypass keeps six 5-20R outlets powered during UPS maintenance using dual 5-20P inputs at 120V 20A
- Product typeBasic
- Hot-swap PDU keeps equipment running during UPS maintenance
- Manual transfer switch selects UPS or utility power instantly
- Dual NEMA 5-20P inputs provide redundant power paths
- Six NEMA 5-20R outlets distribute 120V 20A power
- ECO switching feature reduces energy consumption during operation
Hot-swap PDU for UPS maintenance
The Tripp Lite PDUB201U is a 120V 20A single-phase power distribution unit designed to keep mission-critical equipment running during UPS servicing. Its manual bypass switch transfers connected loads to utility power without interruption. Six NEMA 5-20R outlets support servers and network gear that require continuous uptime.
Dual-input installation with manual transfer
The unit ships with two NEMA 5-20P input cables for UPS and utility sources. Mount the PDU, connect both inputs and plug equipment into the six outlets. The front-panel switch selects Normal or Bypass mode. The only common issue is forgetting to verify both input phases match before switching, which can trip breakers.
Sustained operation under load
During extended bypass periods the PDU passes utility power directly to all six outlets without active conditioning. The 20A rating supports continuous draw up to the branch-circuit limit. No internal batteries or fans are present, so thermal behaviour depends entirely on the connected equipment and ambient airflow.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $177.99
- Cheaper than about 74% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Product type | Basic |
| Size & build | |
| Shipping weight | 3.63 kg |
| Package size | 540 × 210 × 135 mm |
Questions about this item
How can I verify the PDUB201U is passing power correctly after installation?
With the manual transfer switch set to Normal, confirm the UPS input cable is live and the six NEMA 5-20R outlets deliver 120V power to connected equipment.
What cables and plugs are included with the PDUB201U and what must I supply?
The unit ships with two attached input cables ending in NEMA 5-20P plugs for UPS and utility feeds; you must provide NEMA 5-20P cords for each device plugged into the six 5-20R outlets.
Which version of the Tripp Lite hot-swap bypass PDU should I choose for a 15 A branch circuit?
The PDUB201U is rated for 15 A continuous load on a 20 A branch, making it the correct single-phase 120V model for that circuit size.
More in Rackmount PDUs
Similar items
Vertiv VP9567 PDU Basic 15A 120V 14 x 5-15R
- RoHS, UL & c-UL Lis…
- 120 V
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMV15 Metered PDU 15A 16 Outlets 5-15R 120V 5-15P 15ft Cord 0U Vertical
- 0U
- Tested to UL60950-1…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V