Tripp Lite PDUMV30HV2 PDU Metered Vertical 5.8kW 208/240V 8 C19 40 C13 L6-30P 0U TAA
Metered vertical PDU delivers 5.8 kW at 208/240 V through 40 C13 and 8 C19 outlets with dual 20 A breakers and NEMA L6-30P input
- Rack height0U
- Front panel ledsSet of two digital current meters report output current in t
- Certified standardsTested to UL/CAN 60950-1 (USA, Canada), NOM (Mexico), FCC Cl
- Package includesPDUMV30HV2 30A 208/240 V 5.8 kW Single-Phase Metered PDU Plu
- Supply voltage200–240 V
- Input current rating24A
- Dual load banks with 20A breakers protect connected equipment
- Metered current display shows real-time load per segment
- 10 ft input cord with L6-30P plug connects to 208/240V supply
- 40 C13 and 8 C19 outlets support dense rack deployments
- TAA compliant and UL/CAN 60950-1 tested for regulated environments
Metered vertical PDU for 30 A three-phase feeds
The Tripp Lite PDUMV30HV2 is a 0 U vertical power distribution unit rated for 5.8 kW at 208/240 V single-phase input. It accepts a NEMA L6-30P plug on a 10 ft cord and delivers power through 40 IEC C13 and 8 IEC C19 outlets split across two metered load banks. Dual digital current meters on the front panel report output current for each bank so operators can balance loads in real time. The unit ships with plug-lock inserts, mounting hardware and a ground screw for secure rack installation.
Two 20 A breakers protect each outlet bank
Overload protection is provided by a pair of 20 A circuit breakers, one dedicated to Bank 1 and the other to Bank 2, limiting continuous draw to 24 A per agency derating. This breaker arrangement is the single specification that determines whether the PDU matches a facility’s branch-circuit design; each bank serves 20 C13 and 4 C19 outlets, so any rack plan must stay within the 20 A per-bank limit. The input connector, voltage range and breaker ratings are fixed and cannot be altered in the field.
Fanless convection cooling in 0 °C to 50 °C
The PDU operates without fans, relying on passive convection within the stated temperature range of 0 °C to 50 °C and relative humidity of 5 % to 95 % non-condensing. Rated for elevations up to 3000 m, it adds no audible noise to the rack environment and draws only the power required by connected equipment. Certifications include UL/CAN 60950-1, NOM, FCC Class A and TAA compliance, with RoHS adherence confirmed.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $375.99
- Cheaper than about 55% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Tripp Lite |
| Model name | PDUMV30HV2 |
| Product type | Metered |
| Design style | Vertical |
| Display | |
| Front panel leds | Set of two digital current meters report output current in two segments |
| Power | |
| Supply voltage | 200–240 V |
| Input current rating | 24A |
| Input connection | NEMA L6-30P |
| Voltage output | 200 V - 240 V nominal, single phase |
| AC output frequency | 50/60 Hz |
| Output outlets | 40 x C13; 8 x C19 |
| Overload protection | Set of 2 20A breakers protect output Bank 1 and Bank 2 |
| Size & build | |
| Rack height | 0U |
| Cord length | 10 ft (3.05 m) |
| Product dimensions | 70 in × 2.17 in × 2.52 in |
| Product weight | 12.35 lb (5.6 kg) |
| Shipping weight | 8.17 kg |
| Package size | 1930 × 184 × 152 mm |
| In the box | |
| Package includes | PDUMV30HV2 30A 208/240 V 5.8 kW Single-Phase Metered PDU Plug-lock inserts (8 C20, 40 C13) Spare installation buttons, 2.9 mm/4.6 mm Ground screw Mounting hardware Owner's Manual |
| Environment & compliance | |
| Certified standards | Tested to UL/CAN 60950-1 (USA, Canada), NOM (Mexico), FCC Class A (Emissions), TAA Compliant |
| RoHS compliance | Yes |
| Operating conditions | 0 degrees to 50 degrees C |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -15–60 degrees C |
Questions about this item
What does the 5.8 kW rating mean once the unit is installed?
The agency-derated continuous limit is 24 A, so the usable capacity at 208 V is about 5.0 kW and at 240 V about 5.8 kW.
What does the NEMA L6-30P input cap in practice?
The locking plug is rated for 30 A, but the built-in 20 A breakers and the 24 A derating limit continuous draw to 24 A.
What hardware is needed to mount the 0U vertical chassis?
The package includes spare installation buttons for 2.9 mm and 4.6 mm holes, a ground screw and mounting hardware.
More in Rackmount PDUs
Similar items
Tripp Lite PDU1230 PDU 30A 200/208/240V 16C13 4C19 L6-30P 15ft 1U
- 1U
- Tested to UL60950-1…
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
Tripp Lite PDUMH20HVAT PDU 1U ATS 10 Outlets 8xC13 2xC19 2xC20 12ft Cord 200-240V 3.2-3.8kW
- 1U
- 8 front panel LEDs…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V