Tripp Lite PDUV20HVL672 PDU 3.7kW 208/230V 32 C13 6 C19 10ft
A basic PDU distributing 3.7 kW at 208/230 V through 32 C13 and six C19 outlets with a 10-foot NEMA L6-20P cord
- Product typeBasic
- Delivers 3.7 kW to high-density racks via 32 C13 and 6 C19 outlets
- Switchless design prevents accidental shutdowns that cause costly downtime
- 10 ft cord with NEMA L6-20P plug connects to facility power or UPS
- 75 in metal housing mounts vertically in 19 in racks or on walls
- Included C20 and C14 plug-lock inserts keep equipment plugs securely connected
Basic PDU for high-density racks
The Tripp Lite PDUV20HVL672 is a single-phase basic power distribution unit rated at 3.7 kW for 208/230 V input. It delivers network-grade power through 32 C13 outlets and six C19 outlets housed in a 63.75-inch all-metal chassis. A 10-foot cord with an L6-20P plug connects to facility AC, generator or UPS sources.
Suited for dense networking and telecom gear
This unit fits small to mid-sized data centres, computer rooms and network closets where mixed C13 and C19 plugs must be powered from one strip. The switchless design avoids accidental shutdowns, and toolless buttons plus clips allow 0U vertical mounting in EIA 19-inch racks or on walls and counters. Buyers needing metered or switched outlet control should look elsewhere.
32 C13 plus six C19 outlets decide fit
The outlet count and mix determine whether your equipment plugs match without adapters. Verify that your devices use C13 or C19 inlets and that the 3.7 kW rating covers the combined load. The fixed 10-foot L6-20P cord also sets the reach to your power source.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $262.99
- Cheaper than about 64% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Product type | Basic |
| Size & build | |
| Shipping weight | 3.63 kg |
| Package size | 1640 × 123 × 80 mm |
Questions about this item
What does the 3.7 kW rating mean for the equipment I can connect?
The 3.7 kW rating is the maximum continuous load the unit can distribute at 208/240V single-phase. Total connected equipment must not exceed this limit.
What does the NEMA L6-20P input plug cap in practice?
The L6-20P plug connects to a 20 A, 208/240V single-phase source, limiting input current to 20 A and matching the 3.7 kW capacity.
Will the 63.75-inch metal housing fit my 19-inch rack?
Yes, the housing is designed for 0U vertical mounting in an EIA-standard 19-inch rack using the included toolless buttons or clips.
More in Rackmount PDUs
Similar items
Synaccess Networks NP-05B 5-Outlet Switched PDU 1U 15A 120-240V
- 1U
- 120-240 VAC
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
APC AP9560 Basic PDU 1U 100-120V 30A 10x5-20R 12ft
- 1U
- cUL Listed,CSA,UL 6…
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Vertiv MP2-115A Switched 2U Micro Pod PDU 3kVA 120V
- 2U
- MicroPOD MP2-115A B…