Zoro Select 222506 P-Trap No-Hub 1-1/2" Female Socket Cast Iron Pipe
Cast iron P-trap with no-hub female socket connects 1-1/2 inch drainage pipe
- Cast iron construction resists corrosion for long service life
- No-hub design allows quick installation without special tools
- Female socket fits 1-1/2 inch pipe for standard drain connections
- P-trap shape maintains water seal to block sewer gases
- Listed by manufacturer in 2024 as current model
Zoro Select P-Trap 222506
This Zoro Select P-Trap is a 1-1/2 inch cast iron fitting with a female socket and no-hub design. It connects drainage piping in residential or commercial plumbing systems. The cast iron construction provides durability for waste-line installations.
Replaces worn or damaged cast iron traps
Install this trap when an existing no-hub P-Trap shows corrosion, leakage or joint failure. The jump is worth it when the old fitting cannot be cleaned or resealed reliably. No-hub connections allow faster assembly with standard couplings.
Suits plumbers and maintenance teams using no-hub
This fitting suits crews who join pipe with mechanical couplings rather than hub-and-spigot lead joints. It is not for installers who need hubbed fittings, solvent-weld plastic traps or larger diameter drainage components.
How it compares
Measured against everything we stock in Garden Hoses & Pipe Tubing, at today’s prices. Recalculated every night.
- Price $34.99
- Pricier than about 67% of the 973 comparable items (median $21.99).
Specifications
| Product | |
|---|---|
| Brand name | ZORO SELECT |
Questions about this item
What size no-hub coupling fits the 1-1/2 inch female socket on this cast iron P-trap?
A standard 1-1/2 inch no-hub coupling with stainless steel shield and neoprene gasket connects the female socket to adjacent pipe or fittings.
Which step is often missed when installing a no-hub cast iron P-trap like model 222506?
Tightening the coupling bands alternately to the specified torque ensures a uniform seal; skipping the cross-tightening sequence causes leaks.
When should the neoprene gasket inside the no-hub coupling be replaced on this P-trap?
Replace the gasket whenever the joint is disassembled or if seepage appears at the coupling, since the gasket cannot be reused reliably.