Fans, Vents and Climate Control
Free-standing and portable fans, coolers, infrared heaters and the valves, gauges and service parts used on heating and cooling equipment. 328 products from $2.99 to $1,858.99. Dayton, Goodman, Legend Valve and more.
328 products from $2.99
328 results · page 1 of 6
Sort: Featured
JB Industries Quick Coupler 1/4 in Male x Female 90 Deg 33113
REED INSTRUMENTS R2980 Type K air probe for ovens and freezers
Champion Cooler Corp. 310085-10 Aspen Pads 2 for WC44/N44W
Champion Cooler Corp. 324006-107 Louver Side Assembly 16-3/8" x 24-21/32
Champion Cooler Corp. Aspen Pad 32-3/4" x 36-1/4" PK3 air conditioning
Champion Cooler Corp. 324006-106 Louver Side Assembly 22-1/2" x 28-3/4" air conditioning
Champion Cooler Corp. 310085-9 Aspen Pads WC37 RWC35 N37W RN35W
BASO Gas Products L62AA-5 Natural Gas Pilot Safety Switch
Tjernlund Products, Inc. 950-1017 Motor Kit 1 hp 56 Frame 115/208-230V
Tjernlund Products, Inc. 950-0131 Power Venter Motor 1/3 hp
Tjernlund Products, Inc. 950-0428 Duct Fan Motor 1/40 hp 115V AC
Tjernlund Products, Inc. 950-7025 Motor Kit 1/50 hp
Tjernlund Products, Inc. 950-0416 Fan Motor 1/50 hp
Soler and Palau PG-100 Fixed Plastic Grill with Steel Collar 4 inch
Legend Valve 807-035 3/4" Double Wall HE HX200BDW-20 air conditioning
Legend Valve 807-034 3/4" double-wall heat exchanger 14 plate
Legend Valve Heat Exchanger HX160-16 3/4" 16 Plate 70M BTU/H
Legend Valve 807-072 Heat Exchanger HX200-20 20 Plate 100M BTU/H
Legend Valve 807-004 3/4" Double Wall HE HX140-14 air conditioning
Legend Valve 807-002 Heat Exchanger 200 20 Plate 100M BTU/H 3/4
Legend Valve 807-071 HX100-10 10 Plate 50M BTU/H Heat Exchanger
Zoro Select CCT1060-14 straight handle tap 1/4 to 3/4 in 333.5 mm
Westinghouse WES31-1588 Infrared Electric Outdoor Heater Portable Gold
Heater and fan power: wattage, voltage and the outlet
A portable heater or cooler is limited by the circuit that feeds it. In North America a plug-in heater tops out at about 1,500 W because a 120 V, 15 A circuit cannot carry much more for long. Larger units, such as a 3.25 kW infrared heater, usually need 240 V or a dedicated circuit, so read the rated voltage and the plug type before you decide. Wattage describes heat or power draw, not how well a room is covered.
Placement matters as much as power. Free-standing and floor models need clear space around the intake and outlet, tabletop units suit desks and small cabins, and plug-and-play versions need no installation. For ventilation, compare airflow and noise, and choose a vent that can be closed against weather if it will stay open in rain or cold.
Service valves, gauges and refrigerant compatibility
Many items here are tools and parts for heating and cooling systems rather than appliances: access valves, valve core tools, line piercing valves, cap tube gauges and flow switches. A line piercing valve is sized to the outside diameter of the tube it clamps onto, such as 1/2 or 5/8 inch. Match flare sizes and thread standards to the system's service ports.
Refrigerant types are not interchangeable: R-410A systems run at much higher pressure than older R-22 equipment, so gauges, hoses and tools must be rated for the refrigerant in use. Handling refrigerant is regulated in many countries and is work for trained, certified technicians. Flow switches and thermostats are sized by pipe diameter and electrical rating, so read both before you buy.
Questions about Fans, Vents and Climate Control
- How many watts can a portable heater use on a household outlet?
- On a standard 120 V, 15 A circuit, about 1,500 W is the practical maximum for a plug-in heater, and other devices on the same circuit reduce that. Higher-wattage heaters need 240 V or a dedicated circuit and should be installed to the maker's instructions.
- Does a bigger fan always cool better?
- Not necessarily. Moving more air helps, but the right fan depends on the space, the noise and where it sits. Check airflow figures, speed settings and whether it oscillates, and remember that evaporative coolers work best in dry air and add humidity.
- What size line piercing valve do I need?
- Measure the outside diameter of the copper tube, not its nominal size, and pick a valve listed for that diameter, such as 1/2 or 5/8 inch. Use a valve designed for the refrigerant or fluid and the pressure in the line.