We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP7920B Switched PDU 1U 12A 208V 10A 230V 8×C13

SKU CH-3B8J-TGDVG MPN AP7920B

Switched 1U rack PDU with eight C13 outlets, remote on/off control per outlet, 12 A at 208 V or 10 A at 230 V, and a 6.5 ft C14 input cord

  • Connection optionsIEC-320 C14
  • Rack height1U
  • Certified standardscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-
  • Supply voltage200 V, 208 V, 230 V
  • Input line frequency50/60 Hz
  • Input current rating15A
  • Switched outlets enable remote power cycling per device
  • 1U form factor fits standard rack enclosures
  • Digital display shows real-time aggregate current draw
  • Supports 208V and 230V input voltages
  • Eight IEC C13 outlets distribute power to rack equipment

Switched Rack PDU 1U 8×C13

The APC AP7920B is a switched rack power distribution unit that fits a single 1U space. It provides eight IEC 320 C13 outlets with independent on-off control for each connected device. The unit accepts 200-230V input through a front-mounted C14 inlet with a 6.5-foot cord. A digital display shows aggregate current draw in real time.

Suited for remote outlet switching.

Network administrators can reboot individual servers or cycle power to locked-up gear via Web, Telnet, SNMP, SSH or StruxureWare Data Center Expert without visiting the rack. The eight-outlet count limits use in densely populated cabinets that need more than eight C13 connections. The 15A maximum input current and 12A regulatory derated rating restrict total attached load accordingly.

Input-current limit 12A derated

The regulatory derated input current of 12A at 208V or 10A at 230V is the single figure that determines how much equipment the PDU can safely support. Aggregate current shown on the display must remain at or below this limit to avoid tripping the upstream breaker. Operating temperature range is 0-45°C at up to 3000m elevation.

How it compares

Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.

Price $755.99
Pricier than about 67% of the 643 comparable items (median $451.99).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameAPC
Product lineRack PDU
Model nameAP7920B
Product typeSwitched
Storage
Storage elevation0–15000 m
Connectivity
Connection optionsIEC-320 C14
Power
Supply voltage200 V, 208 V, 230 V
Input line frequency50/60 Hz
Input current rating15A
Regulatory derated input current12A
Voltage output208 V, 230 V
Output outlets8 x IEC 320 C13 (Battery Backup)
Size & build
Rack height1U
Cord length6.5 ft (1.98 m)
Product dimensions1.73 in × 17.5 in × 4.25 in
Product weight5 lb (2.27 kg)
Shipping weight4.08 kg
Package size578 × 381 × 114 mm
Environment & compliance
Certified standardscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, UL 60950, UL Listed, VDE
RoHS complianceYes
Operating conditions0–45 degree Celcius
Operating humidity0–95%
Operating altitude0–3000 m
Storage temperature range-25–65 degree Celcius
Storage relative humidity0–95%

Questions about this item

How can I confirm the AP7920B is operating correctly after installation?

The front digital display shows the aggregate current draw in amperes; verify it reads within the 12 A derated limit at 208 V or 10 A at 230 V and that no alarm icons appear.

What ships with the AP7920B and what must I source separately?

The unit includes an attached 6.5 ft (2.4 m) input cord ending in a C14 plug; you must supply eight IEC C13-to-C14 cords for the outlets and a compatible upstream PDU or UPS with a C13 receptacle.

The specs list 12 A at 208 V and 10 A at 230 V — which rating should I plan for?

Plan for the 12 A derated limit when the rack supply is 200–208 V and the 10 A limit when it is 230 V; the PDU auto-ranges across 200 V, 208 V and 230 V inputs.