Burndy Flexible Copper Braid 12 in Grounding Braid with Ferrule
A 12-inch tinned copper grounding braid with ferrules on both ends, rated 190 A indoor and 225 A outdoor, CSA and UL467 listed
- Overall length12 in (30.5 cm)
- Product typeCommercial
- 190 A indoor and 225 A outdoor ampacity for reliable grounding
- Tinned copper braid with copper ferrules resists corrosion
- 12 in overall length with 1 in width fits tight spaces
- Two 0.44 in holes on 1.25 in centres simplify mounting
- UL 467 and CSA listed for code-compliant installations
Flexible Copper Braid for Grounding
The Burndy flexible copper braid is a 12-inch grounding strap designed for commercial electrical installations. Tinned copper construction with ferrules on both ends provides a ready-to-use bond for panels, enclosures or equipment frames. It suits installers who need a listed, flexible conductor for stationary grounding points.
190 A Indoor and 225 A Outdoor Rating
The braid carries 190 amperes indoors and 225 amperes outdoors under the UL 467 and CSA listings. Tinned copper strands dissipate heat across the one-inch width while the ferrules keep contact resistance low at each termination. No forced-air cooling or special derating is required for normal commercial loads.
Two-Hole Ferrule Mounting
Each end has a standard tongue 2 1/2 inches long, 15/16 inches wide and 0.13 inches thick with two holes 0.44 inches in diameter spaced 1.25 inches centre-to-centre and 0.62 inches from the hole centre to the tongue end. The fixed hole pattern suits panels drilled to that spacing; it will not align with single-hole lugs or different centre distances.
How it compares
Measured against everything we stock in Wire, Cable & Wiring Supplies, at today’s prices. Recalculated every night.
- Price $92.99
- Pricier than about 83% of the 1,610 comparable items (median $25.99).
Specifications
| Product | |
|---|---|
| Brand name | Burndy |
| Product type | Commercial |
| Size & build | |
| Overall length | 12 in (30.5 cm) |
Questions about this item
How do I install the 12 in grounding braid and which step is often missed?
Bolt the 0.44 in holes on 1.25 in centres to clean metal, torque to spec, and remember to remove paint or corrosion under each ferrule so the tinned copper makes full contact.
What maintenance or replacement will the braid need over time?
Inspect the tinned copper braid and ferrules annually for corrosion, loose bolts or broken strands; replace the entire 12 in assembly if the braid shows green oxidation or any strand damage.
What limit appears first when the braid carries continuous load?
The 190 A indoor or 225 A outdoor ampacity rating is the first limit; sustained current above that level will overheat the 1 in wide copper braid and ferrules.
More in Wire, Cable & Wiring Supplies
Similar items
3M MNU18-187DFIX Female Disconnect Red 18-22 AWG PK100
- Electrical Connecto…
PREMIERE RACEWAY PRODUCTS Wire Hider FRA-33414 1-1/2" White Right Angle Self Adhesive
3M MNG18-6FBX Fork Terminal #6 Stud 18 AWG 600 V Red 100 Pack
- Electrical Connecto…
PREMIERE RACEWAY PRODUCTS 53414 1-1/2" Outside Corner White Self Adhesive
Blackburn AMTSR500 4-Port Insulated Multitap Connector 4.5 in
- 2-Holes, In Line