Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Class J fast-acting fuse rated 60 A at 600 V AC with a 200 kA interrupt rating
The Bussmann DFJ-60 is a 60 A, 600 V AC Class J fuse designed for fast-acting overcurrent protection in electrical distribution systems. Its cylindrical melamine body measures 2-3/8 in length by 1-1/16 in diameter and fits non-rejection fuse blocks. The single-element construction provides a 200 kA interrupt rating at 600 V AC and 100 kA at 450 V DC.
This fuse suits panels and equipment requiring a 60 A Class J fast-acting link with high interrupt capacity. It is not for circuits needing time-delay characteristics to ride through motor inrush or transformer magnetising current. Buyers who need visual indication of a blown element should select an indicating model instead.
Installation consists of inserting the cylindrical body into a matching Class J non-rejection block such as the CH60J, JM600, JT600 or JTN600 series. Ensure the block is rated for the available fault current and that the fuse orientation matches the holder. The most common error is fitting the fuse into a rejection-style block that physically rejects the non-rejection blade design.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
Compatible fuse block series include CH60J, JM600, JT600 and JTN600, which are designed for the non-rejection style body of this Class J fuse.
Yes, the 200 kA interrupt rating at 600 V AC provides ample margin for legacy gear with lower withstand ratings, while the 100 kA rating at 450 V DC covers older DC systems.
Use a multimeter to measure continuity across the fuse terminals; a low resistance reading confirms the single element is intact and the fuse is ready to protect the circuit.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?