We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 35 A, 600 V AC/DC Class RK5 cylindrical fuse for solar photovoltaic line protection with a 200 kA AC interrupt rating
The Bussmann PVS-R-35 is a fast-acting cylindrical fuse rated at 35 A for 600 V AC and 600 V DC photovoltaic circuits. It carries Class RK5 rejection styling and a 200 kA interrupt rating at 600 V AC, making it suitable for string-level overcurrent protection in commercial and utility-scale solar arrays. Installers specifying to UL 2579 and CSA C22.2 No. 248-12 will find this device listed for those standards.
As a single-element fuse the PVS-R-35 dissipates heat only during fault interruption; normal operation adds negligible thermal load to the combiner or inverter enclosure. The fiberglass body maintains dimensional stability across the temperature range encountered in rooftop and ground-mount installations. No active cooling or derating calculations beyond the published 35 A rating are required for typical string currents.
The 5-1/2 in length and 1-1/16 in diameter match standard Class RK5 fuse blocks, allowing drop-in replacement without panel redesign. Rejection tabs prevent insertion of lower-class fuses, enforcing coordination with the 200 kA AC and 20 kA DC interrupt ratings. Non-indicating construction means visual inspection or a separate monitoring scheme is needed to confirm fuse status after a fault event.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
Insert the 5-1/2 in cylindrical body into a Class RK5 rejection holder until it seats fully; the step often missed is verifying the holder is rated for 600 V DC and 20 kA interrupt before closing the circuit.
The non-indicating, single-element design requires no routine maintenance; replace the fuse only after it interrupts a fault, confirmed by a continuity test on the 35 A element.
The fast-acting element opens at 35 A continuous rating; it will clear an overload at that level before the fiberglass body reaches its temperature limit.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?