Bussmann RM60060-1CR Fuse Block 60A 600V 1 Pole
Single-pole industrial fuse block rated 60 A at 600 VAC with box-lug terminals for 14 to 2 AWG wire
- Product typeCircuit Breakers
- Rated for 600 VAC and 300 VDC industrial circuits
- Accepts 35 to 60 A Class R fuses for reliable overcurrent protection
- Box lug connector handles 14 to 2 AWG wire for secure termination
- Single-pole open design mounts on bolt-down or DIN rail for flexible installation
- Thermoplastic body measures 7.3 in long by 1.5 in wide by 2.6 in high
Bussmann RM60060-1CR Fuse Block 60A 600V
The Bussmann RM60060-1CR is a single-pole fuse block rated for 60 amps and 600 volts AC. It accepts UL Class R fuses in the 35 to 60 amp range and uses box lug connectors for 14 to 2 AWG wire. The thermoplastic body mounts by bolt-down or DIN rail and measures 7.30 inches long, 1.50 inches wide and 2.60 inches high. It suits industrial control panels and generator circuits needing Class R protection.
For panels using FRN, FRS, KTN-R, KTS-R.
This block fits series RM600 fuses and the listed FRN, FRS, KTN-R, KTS-R, LPN and LPS series in a single-pole, open-design layout. Installers who need a different pole count, a different fuse class or a finger-safe cover should look at other models. The 300 volt DC rating also limits use to systems within that bound.
Handles 35 to 60 amp Class R fuses at 600V AC
The block comfortably carries loads up to 60 amps with proper Class R fuses and 14 to 2 AWG conductors. It runs out of capacity above 60 amps or above 600 volts AC, and the 300 volt DC ceiling restricts higher-voltage DC applications. The single-pole format means each phase requires its own block.
How it compares
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
- Price $49.99
- Cheaper than about 55% of the 1,135 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Product type | Circuit Breakers |
Questions about this item
What fuse classes and amp range does the RM60060-1CR block accept?
The block is rated for UL Class R fuses in the 35 to 60 amp range and suits series FRN, FRS, KTN-R, KTS-R, LPN and LPS.
Can I use the existing box-lug wiring when I replace an older 600 V single-pole block?
Yes, the box-lug connector accepts 14 to 2 AWG wire, so the same conductors can be reused.
How do I confirm the block is correctly mounted and making contact after installation?
Verify the bolt-down or DIN-rail mount is secure, check that the fuse seats fully in the open-design clips, and measure continuity across the lugs.
More in Breakers & Circuit Protection
Similar items
myVolts E6B2-CWZ6C 38mm 100P/R incremental encoder line protection
- AT
OEM Industries RO14 RT19-16 gF1 1A 500V 100KA Ø8*32mm Ceramic Fuse 20pcs
- Circuit Protectors
- Box
OEM Industries RO21 E27 RL6-25 RL93 RLS2 5SD 5SB 20A 500V 50KA Spiral-style ceramic fuse 10 pcs
- Circuit Protectors