Dynaquip Controls PHS27AJS064A 115V AC pneumatic ball valve trap
Pneumatically actuated 115V AC stainless steel ball valve with full port design and 1,000 psi operating pressure
- Product typeDrain Components
- Main materialHAWA
- Pneumatically actuated for automated flow control
- 316 stainless steel ball resists corrosion
- Full-port design maintains unrestricted flow
- 115V AC pilot solenoid included for direct wiring
- Fail-safe spring return closes valve on air loss
Pneumatically Actuated Ball Valve
This pneumatically actuated two-way ball valve uses a 115V AC pilot solenoid for control. It suits process lines that require automated on-off flow management with a fail-safe design. The unit arrives new and ready for installation in compatible stainless steel piping systems.
Operating Pressure Limits
The valve handles a maximum operating pressure of 1,000 psi and a maximum steam pressure of 150 psi. These ratings define the practical ceiling for air, gas, liquid or steam service in the line. Exceeding either limit risks seat damage or body deformation regardless of the actuator condition.
Normally Closed Fail-Safe Action
The actuator operates on an air-to-spring principle with a normally closed de-energised state. Loss of air supply or electrical signal to the solenoid drives the valve to the closed position automatically. Systems that must fail open or require double-acting actuation cannot use this valve.
How it compares
Measured against everything we stock in Drain Stoppers, Strainers & Traps, at today’s prices. Recalculated every night.
- Price $488.99
- Pricier than about 90% of the 4,240 comparable items (median $31.99).
Specifications
| Product | |
|---|---|
| Brand name | Dynaquip Controls |
| Model name | PHS27AJS064A |
| Product type | Drain Components |
| Size & build | |
| Main material | HAWA |
Questions about this item
Which Dynaquip PHS27AJS064A variant should I choose for a 115V AC supply?
The PHS27AJS064A model includes a 115V AC pilot solenoid, so select this version when your control circuit runs on 115V AC.
What does the 1,000 psi operating pressure mean when the valve is installed in a live pneumatic line?
The valve body and 316 stainless steel ball are rated for 1,000 psi maximum operating pressure in normal service.
How does the 1-1/2 in FNPT connection limit the pipe size I can use?
The valve has a 1-1/2 in FNPT end connection, so it mates directly with 1-1/2 in male NPT pipe threads.
More in Drain Stoppers, Strainers & Traps
Similar items
HAYWARD POOL PRODUCTS INC SV20050STV 120VAC CPVC Solenoid Valve Trap
- Drain Components
- CPVC
Banjo RB300-150 3 inch MNPT x 1-1/2 inch FNPT Reducing Bushing Schedule 80 trap
BELL AND GOSSETT PL-36 trap 1/6 hp 115V
- Drain Components
- Cast Iron