We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton 9PX3000RT 3000 VA 2700 W 2U UPS L5-30P 6×5-20R 1×L5-30R 120V

SKU CH-FQEV-X1QAG

Online double-conversion UPS delivers 3000 VA and 2700 W with 93% efficiency, 2U rack/tower form, L5-30P input, six 5-20R and one L5-30R outputs, 14-minute half-load runtime

  • Voltage version120 V
  • AC input voltage100–144 V
  • Input line frequency50/60 Hz
  • Power inputNEMA L5-30P
  • Volt-ampere rating3000 VA
  • Power rating2700 W
  • Online double-conversion topology provides zero transfer time to battery
  • 9 power factor delivers 2700 W real power from 3000 VA rating
  • Up to 98 % efficiency in Energy Saver System mode cuts utility and cooling costs
  • Rotating graphical LCD shows load, runtime and diagnostics at a glance
  • ABM charging technology extends battery service life

3000 VA online UPS for critical servers

The Eaton 9PX3000RT is a 2U rack or tower UPS with online double-conversion topology that provides zero transfer time to battery. It accepts 100 to 144 V input through a NEMA L5-30P plug and delivers 120 V output from six NEMA 5-20R outlets and one NEMA L5-30R outlet. The unit operates at up to 93 percent efficiency in normal mode and up to 98 percent in ESS mode. A rotating graphical LCD shows load, runtime and diagnostics without software.

Suits racks needing 2700 W conditioned power

This UPS fits 2U spaces where servers, storage or network gear require clean 120 V power with surge and frequency protection. The twist-lock input and mixed 20 A and 30 A outlets support diverse power cords in edge data centres or equipment closets. Buyers who need longer runtime at full load than five minutes should consider external battery modules. Sites without a 30 A 120 V circuit cannot use the L5-30P input connection.

0.9 power factor yields 2700 W real power

The 0.9 power factor means the 3000 VA rating translates to 2700 W of usable output, higher than units with lower factors. This single figure determines whether the UPS can handle your actual server load without derating. Verify that your equipment's total wattage stays below 2700 W and that the 14 minute half-load or 5 minute full-load runtime meets your shutdown window.

How it compares

Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.

Price $842.99
Typical for this category: the median of 1,153 items is $948.99.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Specifications

Product
Brand nameEATON
Model name9PX3000RT
Power
Voltage version120 V
AC input voltage100–144 V
Input line frequency50/60 Hz
Power inputNEMA L5-30P
Volt-ampere rating3000 VA
Power rating2700 W
Voltage output120 V
Power outlets7
Runtime on batteryAt half load: 14 minutes
At full load: 5 minutes
Replacement battery9PXEBM72RT
Size & build
Product dimensions3.4 in × 17.3 in × 23.8 in
Product weight63.1 lb (28.6 kg)
Environment & compliance
Regulatory approvalsIEC 62040-2 Cat C1 / CISPR22 / FCC part 15 Class B / VCCI Class B

Questions about this item

How much heat and fan noise does the 3000 VA online double-conversion UPS produce when running continuously at full load?

The unit operates at up to 93% efficiency in normal online mode and up to 98% in Energy Saver System mode, meaning only a small fraction of the 2700 W output becomes waste heat; the graphical LCD rotates for rack or tower viewing so you can monitor load and temperature without opening the rack.

What input circuit and receptacle must already be installed on site for the NEMA L5-30P plug to connect?

A dedicated 120 V, 30 A branch circuit with a matching NEMA L5-30R receptacle is required; the twist-lock plug will not fit a standard 5-20R or 5-15R outlet.

Can the six NEMA 5-20R outlets and the single NEMA L5-30R outlet power legacy servers that only have 5-15P cords?

Yes — 5-15P plugs fit into 5-20R receptacles, and the L5-30R outlet accepts an L5-30P cord; for 5-15P devices on the L5-30R you would need a suitable adapter or PDU, but the UPS itself delivers 120 V compatible with older gear.