Eaton EMA113-10 Managed PDU 8-Outlet 1.92 kVA 120 V
Distributes 1.92 kVA at 120 V across eight NEMA 5-20R outlets from dual NEMA 5-20P and L5-20P inputs
- Supply voltage120 V AC
- Product typeOthers
- Key featuresProduct Name:ePDU Managed 8-Outlet PDU Output Receptacles:8
- 8 outlets deliver reliable 120 V power to rack equipment
- 92 kVA capacity supports dense server deployments
- Managed series enables remote monitoring and control
- Vertical 0U form factor preserves rack space for IT gear
- Dual input cords NEMA 5-20P and L5-20P provide flexible site installation
Rack-mount power distribution for 120 V circuits
The Eaton EMA113-10 is a vertical managed PDU rated at 1.92 kVA on a 120 V AC supply. Eight NEMA 5-20R outlets deliver power to rack-mounted equipment from a single 20 A input. Network management allows remote outlet switching and monitoring.
Suited for 20 A single-phase racks
This unit fits cabinets that use NEMA 5-20P or NEMA L5-20P feeds and need eight 20 A receptacles. It is not for installations that require a different input connector, more than eight outlets, or a higher power rating.
1.92 kVA at 120 V AC
The 1.92 kVA rating defines the maximum load the PDU can support on a 120 V circuit. Exceeding this limit will trip the upstream breaker, so the connected equipment must stay within the rated capacity.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $819.99
- Pricier than about 70% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Eaton |
| Product line | Managed |
| Product type | Others |
| Power | |
| Supply voltage | 120 V AC |
| Size & build | |
| Shipping weight | 4.99 kg |
| Package size | 1194 × 254 × 203 mm |
Questions about this item
What plugs and cables come with the EMA113-10 and what must I supply?
The unit includes a vertical chassis with eight NEMA 5-20R outlets and two input plugs — one NEMA 5-20P and one NEMA L5-20P — so no input cable is required; you only need to provide the IEC or NEMA cords that connect your equipment to the 5-20R receptacles.
The specs show two different input plugs — 5-20P and L5-20P — which one should I use for a 120 V 20 A circuit?
Use the NEMA L5-20P locking plug for a dedicated 120 V 20 A branch circuit; the straight-blade 5-20P is an alternate connection for receptacles that do not accept a locking plug, but both are rated for the same 1.92 kVA capacity.
What does the 1.92 kVA rating mean for the actual load I can connect to the eight outlets?
At 120 V the 1.92 kVA rating equals a 16 A continuous current budget, so the combined draw of all devices plugged into the eight NEMA 5-20R outlets must stay at or below 16 A to avoid tripping the internal breaker.
More in Rackmount PDUs
Similar items
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
APC AP8870 Metered PDU 120/208V 30A 16x5-20R 12xC13/C19 0U
- 120 V AC, 230 V AC
- 120 V AC
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
Eaton Metered EMIT05-10 16-Outlet PDU 5.76 kVA 230 V AC
- 230 V AC
- 230 V AC