Eaton EMAU06-10 Managed PDU 2U 16 Outlet 12 C13 4 C19 L6-30P 5.76 kVA
A 2U rackmount PDU delivers 5.76 kVA through twelve C13 and four C19 outlets from a single L6-30P input with dual 20A breakers
- Supply voltage230 V AC
- Key featuresOutput Receptacles:12 x IEC 320-C13 4 x IEC 320-C19 Product
- Managed 16-outlet power distribution for dense rack deployments
- 76 kVA capacity supports high-density server and network equipment
- 12 C13 and 4 C19 outlets fit mixed IEC power cords
- Dual 20 A circuit breakers protect connected loads
- Horizontal 2U form factor installs in standard 19-inch racks
16-Outlet Managed PDU for 2U Racks
The Eaton EMAU06-10 is a horizontal rackmount power distribution unit designed for 2U server cabinets. It provides managed power delivery to critical IT equipment in data centres and network closets. The unit operates on a 230 V AC input and supports a 5.76 kVA power rating.
L6-30P Input with Mixed C13 and C19 Outputs
A single NEMA L6-30P plug connects the PDU to a compatible upstream power source such as a UPS or wall circuit. Twelve IEC 320-C13 and four IEC 320-C19 receptacles supply attached servers, switches and storage arrays. Two 20 A circuit breakers protect the load banks.
Monitored Operation with Breaker Protection
Managed functionality enables remote monitoring of power consumption and environmental conditions across the rack. The dual 20 A breakers isolate faults without shutting down the entire strip. The horizontal form factor keeps cable routing tidy inside standard enclosures.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $857.99
- Pricier than about 71% of the 643 comparable items (median $451.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Eaton |
| Product line | Managed |
| Model name | EMAU06-10 |
| Power | |
| Supply voltage | 230 V AC |
| Size & build | |
| Shipping weight | 9.07 kg |
| Package size | 483 × 343 × 89 mm |
Questions about this item
At what sustained load do the two 20 A circuit breakers on the EMAU06-10 trip?
Each circuit breaker trips at 20 A; the unit provides two breakers protecting separate outlet banks.
How much heat and fan noise should I expect when this PDU runs continuously at full 5.76 kVA capacity?
The PDU is a passive distribution unit with no built-in fans, so it adds no audible noise and only minimal heat from conductor losses.
What input receptacle must my rack supply to match the NEMA L6-30P plug on this unit?
The PDU requires a NEMA L6-30R outlet fed by a 230 V AC, 30 A circuit.
More in Rackmount PDUs
Similar items
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
CyberPower CPS1215RM 120V 15A Basic PDU 10 Outlets 15ft NEMA 5-15P 1U
- 1U
- 1U
CyberPower PDU44003 Switched ATS PDU 2U 2xL5-30P 16x5-20R 1xL5-30R
- Switched
- Horizontal
Tripp Lite PDUMV20 Metered PDU 20A 28 Outlets 120V 15ft 0U Vertical
- 0U
- 120 V
CyberPower PDU44005 Switched 1U 200-240V 20A 10ft PDU
- 1U
- 200–240 V