We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Thermal overload unit covering 2.11 to 2.32 A for NEMA 0, 1, 2 starters
The Eaton FH23 thermal unit provides overload protection for motor starters and contactors. It covers a full-load current range of 2.11 to 2.32 amperes and suits NEMA sizes 0, 1 and 2. Electrical technicians and panel builders use it to replace worn or damaged heater elements in compatible assemblies.
This unit operates at Trip Class 20, meaning it trips within a defined time under sustained overcurrent. The thermal mechanism reacts to heating from load current rather than ambient temperature alone. Power draw is negligible because the element is passive and carries only the motor current.
Under continuous overload the element heats progressively and opens the control circuit when the trip threshold is reached. It does not reset automatically; the starter must be manually re-engaged after the fault clears. The 1.79 to 1.95 A and 2.07 to 2.26 A ratings apply to other models in the same series.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Eaton |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
Snap the unit into the overload relay base for NEMA size 0, 1 or 2 starters; the step often missed is verifying the full-load current falls within the 2.11-2.32 A range before closing the cover.
Replace the thermal unit after a trip event or when the heater element shows discolouration; no lubrication or cleaning is required for the sealed Trip Class 20 element.
The thermal element reaches its Trip Class 20 time-current limit first, opening the circuit when current exceeds the 2.11-2.32 A rating for the defined trip time.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?