We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Thermal overload unit rated 9.36 to 10.3 A, Trip Class 20, fits NEMA sizes 1, 3, 4, 5 and Series MS starters
The Eaton MSH11-7A is a thermal overload unit rated for Trip Class 20 with a full-load current range of 9.36 to 10.3 A. It fits NEMA Size 1, 3, 4, and 5 starters and is compatible with Series MS devices. Industrial maintenance teams and panel builders use it to replace worn or tripped elements in existing motor control gear.
Trip Class 20 defines the maximum time the unit allows an overload before tripping, which is slower than Class 10 or Class 5 units. This characteristic suits motors with longer acceleration cycles but will not protect fast-trip requirements. Installers must verify that the application’s startup profile matches Class 20 timing to avoid nuisance trips or insufficient protection.
The decisive specification is the 9.36 to 10.3 A full-load current window; the unit will not protect motors operating outside this band. Buyers needing coverage for lower or higher current motors must select a different thermal unit. Compatibility with the listed Series MS and Grainger part numbers confirms mechanical fit, but electrical sizing remains the single factor that decides suitability.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Eaton |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
This thermal unit is fixed at Trip Class 20 and covers a full-load current range of 9.36 to 10.3 A; choose it only when your motor’s nameplate current falls inside that window.
Trip Class 20 allows the motor to run at locked-rotor current for roughly 20 seconds before the thermal unit opens, giving a slower response than Class 10 or 5 units.
It is compatible with NEMA Sizes 1, 3, 4 and 5 and works with Eaton Series MS starters, including the MST01 and MST02 model families listed.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?