Eisco Scientific CH0993LP Anti-Tip Bunsen Burner LP laboratory supply
Anti-tip Bunsen burner for LP gas with adjustable output from 2000 to 3200 BTU and maximum temperature of 1500 °C
- Anti-tip design keeps the burner stable during use
- Adjustable gas control delivers 2000 to 3200 BTU output
- Maximum temperature reaches 1500 °C for demanding applications
- 8 mm barb fits standard laboratory tubing connections
- Cast-iron base provides durability and heat resistance
Anti-Tip Bunsen Burner for LP Fuel
The Eisco Scientific CH0993LP is a laboratory burner designed for use with liquefied petroleum gas. Its cast-iron base provides a stable platform that resists tipping during routine bench work. The unit delivers a heat output ranging from 2000 to 3200 BTU and can reach a maximum temperature of 1500 degrees Celsius. It suits educational and professional labs needing a reliable open-flame heat source.
8 mm Barb Connection for Gas Supply
The single specification that determines compatibility is the 8 mm barb fitting on the gas inlet. This size must match the internal diameter of the laboratory's LP gas tubing to ensure a secure, leak-free connection. No other hose size will seat correctly on this fitting. Verify the tubing specification before installation to avoid unsafe operation.
Fits Standard Bench Setups with LP Gas
The burner stands 6 3/4 inches tall with an 11 mm outside diameter, dimensions that suit typical laboratory bench clearances. It requires an existing LP gas line terminated with compatible 8 mm tubing and a suitable regulator valve. The cast-iron base frees the user from needing a separate stand or clamp to keep the burner upright. No electrical supply or additional mounting hardware is required for operation.
How it compares
Measured against everything we stock in Lab Equipment & Supplies, at today’s prices. Recalculated every night.
- Price $28.99
- Cheaper than about 73% of the 734 comparable items (median $60.99).
Specifications
| Product | |
|---|---|
| Brand name | EISCO SCIENTIFIC |
Questions about this item
What does the 2000 to 3200 Btu output mean for actual heating tasks?
The burner delivers 2000 to 3200 Btu, giving a maximum flame temperature of 1500 degrees C for typical laboratory heating.
How does the 8 mm barb size limit the gas supply connection?
The 8 mm barb fits standard LP tubing of that inner diameter, so the gas line must match this size for a secure connection.
What space does the 11 mm outside diameter and 6 3/4 in height require on a bench?
The cast-iron base measures 11 mm in outside diameter and the unit stands 6 3/4 inches tall, so allow that footprint and vertical clearance.
More in Lab Equipment & Supplies
Similar items
ILIHOME T57-b Digital Microscope 2.0" IPS Screen 12 Pack Orange
- T57a Digital Magnif…
- 500 Wh
Legend Valve 316-200 3" x Close 316 Stainless Steel Pipe Nipple laboratory supply
Rongon TA-023 2.5X 5X 16X Magnifying Glass Set laboratory supply
- 4.2926 cm × 20.701…
- 2.5 multiplier x





