We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Single-pole bolt-on breaker rated 45 A at 277/480 V AC with 14 kA interrupting capacity for GE AE lighting panels
This GE bolt-on breaker provides 45 A overcurrent protection for single-phase 277/480 V AC panels. It fits GE AE lighting panelboards using the TEY frame and mounts directly onto the bus without a separate adapter. The thermal-magnetic trip unit offers fixed instantaneous response for consistent fault clearing.
The thermal element carries 45 A continuously while warming at the same rate as downstream conductors. Under prolonged overload the bi-metal strip bends gradually to open the contacts before insulation degrades. A 14 kA interrupting rating at 277 V AC ensures the breaker survives high fault currents without contact welding or case rupture.
Operation is restricted to 277 V AC phase-to-neutral or 480 V AC phase-to-phase systems with a 125 V DC option. The 125 A TEY frame caps the maximum trip setting at 250 A, so the device cannot protect conductors rated above that threshold. Lug terminals accept wire sizes suited to the 45 A rating only.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Ge |
| Product type | Circuit Breakers |
The thermal-magnetic trip unit is calibrated for 45 A continuous current; heat output is governed by the 125 A frame rating and the 14 kA interrupting capacity at 277 V AC, so the breaker meets standard panelboard temperature-rise limits without additional derating.
It requires a GE AE lighting panel with a 125 A TEY-series bus that accepts bolt-on, single-pole breakers on any phase connection.
The fixed instantaneous setting of 250 A provides a consistent magnetic threshold; coordination with older downstream devices depends on their own trip curves and the available fault current, which is limited to 14 kA at 277 V AC by this breaker's interrupting rating.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?