Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Three-pole molded-case breaker rated 15 A at 277/480 V AC with 14 kA interrupting capacity and thermal-magnetic trip
The GE TEY315 is a 15 A molded-case circuit breaker built for three-phase 277/480 V AC panels and rated for 250 V DC. It carries a 14 kA interrupting rating at 277/480 V AC and fits GE AE lighting panelboards using a bolt-on mounting style. The frame size is 125 A and the fixed instantaneous trip is set at 575 A.
A thermal-magnetic trip unit provides overload and short-circuit protection without adjustment. The fixed instantaneous setting means the breaker opens at 575 A without user calibration. Lug terminals accept standard conductor connections, simplifying wiring in the panel.
The breaker measures 5.25 in high, 3 in wide and 3.06 in deep, matching the TEY series footprint for GE AE lighting panels. Bolt-on mounting secures the device directly to the panelboard bus, reducing movement during vibration. Three-pole ABC phase connection covers balanced three-phase loads in commercial and light-industrial distribution.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
The bolt-on panelboard mounting and lug terminals should be checked for proper torque at initial installation and after the first load cycle; no scheduled re-torquing interval is published by GE.
The thermal-magnetic trip unit is calibrated for a 15 A continuous rating with a fixed instantaneous pickup at 575 A; the 125 A frame size defines the maximum interrupting capacity of 14 kA at 277/480 V AC.
At 15 A the thermal element dissipates only a few watts, so temperature rise inside a GE AE lighting panel stays well within the 125 A frame design limits during continuous operation.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?