Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Three-pole molded case breaker rated 60 A at 277/480 V AC with 14 kA interrupting capacity, thermal-magnetic trip, bolt-on mounting for GE AE lighting panels
The GE TEY360 is a molded-case circuit breaker rated at 60 amperes with three poles for 277/480 V AC systems. It provides standard thermal-magnetic trip protection for commercial and industrial panelboards. The unit mounts by bolt-on connection into compatible GE AE lighting panels.
The breaker carries a maximum AIR rating of 14 kA at 277/480 V AC, suitable for available fault currents up to that level. Its 125 A frame size sets the physical and thermal limit, while the fixed instantaneous trip is set at 250 A. Continuous loads above 60 A or fault currents above 14 kA exceed the device ratings.
The breaker uses a bolt-on panelboard mounting style with lug terminal connections and ABC phase arrangement. It requires a GE AE lighting panel enclosure with matching bus geometry and three-pole space. The compact 5.25 by 3 by 3.06 inch profile fits standard panelboard gutters without additional clearance.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
Yes, the TEY360 is built for GE AE lighting panels and uses the 125 A TEY frame size, so it bolts directly into the same panelboard without adapter kits.
With the circuit energised, measure voltage across each of the three poles; all should read within the 277/480 V AC rating. Apply a known load up to 60 A and confirm the thermal-magnetic trip remains closed; the fixed instantaneous trip will only open above the 250 A high amp setting.
The breaker ships with the terminal connection lugs already fitted, so no additional lug kit is required for standard cable termination.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.