We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 50 A, single-pole miniature breaker rated 120/240 V AC with 10 kA interrupting capacity, bolt-on mounting and UL listing
The GE THQB1150 is a miniature circuit breaker rated at 50 amps for 120/240V AC systems. It uses a single-pole, bolt-on design from the THQB series with a 10kA interrupting rating. The toggle actuator provides manual switching for lighting panels and load centers. UL Listed construction supports copper wire from 14 to 8 MCM and aluminum from 12 to 8 MCM.
This breaker suits electricians wiring standard lighting panels or load centers that accept THQB bolt-on frames. It is not for buyers who need DC voltage protection or multi-pole configurations for 240V-only loads. Installers requiring a higher AIR rating or a different mounting style such as plug-in should look at other series.
The maximum interrupting rating of 10kA determines whether this breaker can safely clear a fault in your panel. Verify that the available fault current at the installation point does not exceed this value. The bolt-on mounting and THQB frame size of 100A must match the load center specifications for a secure fit.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
The breaker measures 3.5 in long, 1 in wide and 3.3 in deep, so the panel cut-out must accommodate those dimensions for a secure bolt-on fit.
Tighten the lug terminals to the torque printed on the breaker label; the 8 MCM maximum wire size is rated for the 50 A, 120/240 V AC circuit.
Replace the breaker if it has tripped on a short-circuit at the 10 kA interrupting rating or shows any contact erosion, as repeated high-current trips degrade the toggle mechanism.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?