Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Miniature circuit breaker rated 90 A, two-pole, 120/240 V AC with 10 kA interrupting capacity, bolt-on mounting for lighting panels and load centres
The GE THQB2190 is a miniature circuit breaker rated at 90 amps for 120/240V AC systems. It uses a bolt-on mounting style designed for compatible load centres and lighting panels. The unit carries a UL listing and a 10kA interrupting rating at the rated voltage. A toggle actuator provides manual switching for standard branch-circuit protection.
This breaker fits installations that require a 90-amp, two-pole device on a 100A frame. It is not for circuits needing a different amperage, a three-pole configuration, or DC voltage ratings. Builders needing plug-on mounting or higher interrupting capacity should look at other models. The fixed 90A rating also means it cannot serve adjustable-trip applications.
The maximum ampere interrupting rating of 10kA at 120/240V AC determines whether this breaker can safely clear faults in your panel. Verify that your system’s available fault current does not exceed this value. The rating is the primary specification for code-compliant selection in residential and light-commercial load centres.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | GE |
Yes — the THQB2190 uses a bolt-on mounting style and a 100 A frame size, so it installs directly into compatible GE load centers designed for the THQB series.
The lug terminals accept wire from 6 AWG up to 1/0 AWG, so 1/0 AWG copper is within the rated range for each pole.
With the toggle in the ON position, measure voltage across each pole to confirm 120 V to neutral and 240 V between poles, then apply a known load up to 90 A and confirm the breaker holds without nuisance tripping.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?