Hayward Flow Control BFA2007SFS Bulkhead Tank Fitting 3/4 inch CPVC FKM Socket
A CPVC bulkhead tank fitting with FKM gasket, 3/4 inch socket connections and a 150 psi pressure rating
- Product typePipes, Valves & Fittings
- CPVC construction resists corrosion in harsh chemical environments
- FKM gasket withstands temperatures from 40 to 190 degrees Fahrenheit
- Rated for 150 psi maximum operating pressure in demanding systems
- Socket connections on both ends simplify installation on curved or flat tanks
- Hayward Flow Control engineering ensures reliable bulkhead sealing performance
Bulkhead Tank Fitting 3/4 Inch CPVC
This bulkhead tank fitting provides a 3/4 inch socket connection for CPVC piping systems. It is designed for installation on curved or flat tank walls using FKM gasket material. The fitting suits plumbing applications requiring a reliable pass-through connection.
Replaces Worn Tank Penetrations
Upgrade when an existing bulkhead fitting shows signs of leakage or material degradation at the tank wall. The jump is worth it when the current seal no longer holds the required pressure or temperature range. CPVC construction with FKM gaskets restores a secure seal for continued service.
CPVC Pressure and Temperature Limits
The fitting handles a maximum operating pressure of 150 psi across a temperature range of 40 to 190 degrees F. CPVC material properties define the upper boundary for hot fluid service. Operating beyond these limits risks fitting failure and system leaks.
How it compares
Measured against everything we stock in Faucet Valves & Replacement Parts, at today’s prices. Recalculated every night.
- Price $34.99
- Cheaper than about 67% of the 1,132 comparable items (median $54.99).
Specifications
| Product | |
|---|---|
| Brand name | HAYWARD FLOW CONTROL |
| Product type | Pipes, Valves & Fittings |
Questions about this item
What tank wall thickness can the Hayward BFA2007SFS bulkhead fitting accommodate?
The fitting mounts on both curved and flat tank walls with zero bolt holes, sealing via the FKM gasket against the tank surface.
Which solvent cement should I use for the 3/4 inch CPVC socket connections?
Use only CPVC‑rated solvent cement; prime both socket and pipe, insert fully, hold for the cement manufacturer’s set time, and avoid over‑tightening the joint.
When should the FKM gasket be inspected or replaced?
Inspect the gasket annually or after any pressure spike above 150 psi; replace if it shows cracking, hardening, or leakage at the tank seal.
More in Faucet Valves & Replacement Parts
Similar items
KINGSTON BRASS K132A0 2.25" Adjustable Shower Head, Matte Black
- Tools
KINGSTON BRASS K132A3 2.25" Adjustable Shower Head Antique Brass
- Tools





