HNZXIB 86 °C 108L Vertical Ultra Low Temperature Freezer 110V
A vertical ultra-low temperature freezer reaching -86 °C with a 108 L stainless-steel chamber, Secop compressor and microcomputer control adjustable in 0.1 °C steps
- Rated voltage110 V
- Precise digital control adjusts temperature in 0.1 °C steps
- Secop compressor and EBM silent fan maintain -86 °C stability
- 304 stainless steel interior resists corrosion for safe sample storage
- 108 L capacity with 460×460×510 mm chamber fits diverse lab loads
- Intelligent alarm system alerts on over-temperature, door-open and power-loss events
Purpose & Audience
The HNZXIB 86 °C 108L vertical ultra-low temperature freezer is built for scientific research institutions, universities, and industrial labs that require stable deep refrigeration. It suits users storing special materials, biological samples, or electronic components at -86 °C.
Build Integration
The unit runs on 110V power and draws 480 W, so it needs a compatible circuit. Its exterior measures 700*730*1260 mm and weighs 107 kg, while the 304 stainless steel interior provides 108 L of usable space at 460*460*510 mm. Heavy-duty casters allow repositioning, and goods must stand for 12 hours before the first start-up.
Thermals, Noise & Power
A Secop compressor and EBM silent fan maintain the -86 °C set point with microcomputer control adjustable in 0.1 °C steps. An ultra-thick insulation layer reduces heat loss, while an intelligent alarm system covers high and low temperature events, with optional door-open and power-off alerts.
How it compares
Measured against everything we stock in Lab Equipment & Supplies, at today’s prices. Recalculated every night.
- Price $3,306.99
- Pricier than about 90% of the 734 comparable items (median $60.99).
Specifications
| Power | |
|---|---|
| Rated voltage | 110 V |
Questions about this item
How long must the 86 °C 108L freezer stand before the first start-up?
The unit must stand for 12 hours after delivery before it is switched on.
What noise level can be expected from the EBM silent fan during continuous operation?
The EBM silent fan is designed for quiet running, keeping audible noise low during all-day use.
Which power supply must already be available on site for this 110V model?
A 110 V mains supply capable of delivering 480 W is required.
More in Lab Equipment & Supplies
Similar items
HNZXIB S-30L 30L 220V Jacketed Glass Reactor laboratory supply
- 30L
- 220 V
Legend Valve 316-200 3" x Close 316 Stainless Steel Pipe Nipple laboratory supply
HNZXIB 60L Stainless Steel Jacketed Reactor Stirring Kettle with Observing Window
- 220 V
Legend Valve 316-074 1/2" x 10" 316 SS Nipple laboratory supply
HNZXIB RE501 Rotary Evaporator & -10°C/10L Chiller DLSB10/10 110V/60Hz
- 5L
- 110 V