Milwaukee Valve 10SSOD-02-LL 1/2 in Fire Safe Ball Valve
Stainless steel fire-safe ball valve rated for 2,000 psi operating pressure and 150 psi steam with locking handle
- Fire-safe design handles steam up to 150 psi
- One-piece stainless steel body withstands 2,000 psi operating pressure
- Locking handle prevents accidental operation during service
- Carbon steel ball with standard port controls combustible gases and water
- Full vacuum capability rated to 29.92 in Hg
Valve Specifications
The Milwaukee Valve 10SSOD-02-LL is a manual two-way ball valve built with a stainless steel body and a carbon steel ball. It features a one-piece straight body design and a locking handle for secure operation. The valve carries a fire-safe rating for critical safety applications.
Intended Use and Limitations
This valve suits plumbing and industrial systems that handle water or combustible gases at high pressure. It is not for installations requiring 3-A sanitary compliance or where average surface roughness data is mandatory. Buyers needing certified sanitary finishes or non-locking handles should look elsewhere.
Decisive Pressure Rating
The maximum operating pressure is 2,000 psi for general service and 150 psi for steam duty. This pressure ceiling determines whether the valve matches the system design. Confirm the service pressure before purchase.
How it compares
Measured against everything we stock in Faucet Valves & Replacement Parts, at today’s prices. Recalculated every night.
- Price $64.99
- Typical for this category: the median of 1,132 items is $54.99.
Specifications
| Product | |
|---|---|
| Brand name | MILWAUKEE VALVE |
| Product type | Other |
Questions about this item
How do I install the 1/2 in FNPT stainless steel ball valve, and what step is often missed?
Thread the valve onto the 1/2 in FNPT connections using pipe sealant rated for 2,000 psi service; the step often missed is verifying the flow arrow matches the system direction before final tightening.
What maintenance or replacement will the carbon steel ball and locking handle need over time?
Inspect the carbon steel ball and stem seals annually for wear from combustible gases or water; replace the valve if leakage appears at the stem or ball seats, as the one-piece body cannot be rebuilt.
Which limit appears first during sustained high-pressure use — the 2,000 psi operating rating or the 150 psi steam rating?
The 150 psi steam limit is reached first; sustained steam service above that pressure will exceed the valve rating before the 2,000 psi operating limit becomes a factor.
More in Faucet Valves & Replacement Parts