We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 100 A, 690 V fast-blow ceramic fuse with bolted joint rated for 50 kA interrupting capacity
The OEM Industries GSG RGS4 is a cylindrical ceramic-tube fuse rated at 100 amps and 690 volts with a 50 kA breaking capacity. It uses a bolted-joint design for secure mounting in industrial power circuits. Electrical engineers and maintenance teams specify it for line protection where rapid fault clearing is required.
The fast-blow characteristic clears short-circuit current faster than standard gG or gL fuses, reducing let-through energy to downstream equipment. The step up is justified when protecting semiconductor drives, rectifiers or other aR-rated loads that cannot withstand the thermal impulse of a slower fuse. Installations staying within gG coordination curves do not need this rating.
The fuse body fits into compatible bolted fuse bases; torque the mounting bolts to the base manufacturer's specification to avoid hot spots. A common error is re-using a base with pitted contacts, which raises resistance and causes nuisance opening. Verify that the system voltage does not exceed 690 V and that the prospective fault current is within the 50 kA interrupting rating.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Product line | GSG RGS4 |
| Model name | GSG RGS4 |
| Product type | Circuit Protectors |
| Power | |
| Amperage | 100 |
The fuse uses a bolted joint on a cylindrical ceramic body; match the holder to the 100A aR 690V rating and verify bolt centres before mounting.
Install with the ceramic tube vertical or horizontal as the panel allows, tighten both bolted joints to the manufacturer’s specified torque, and confirm the 50KA interrupt rating is not exceeded.
A fast-blow ceramic fuse that has interrupted a 50KA fault must be replaced; inspect the bolted contacts for pitting and fit a new 100A aR 690V unit before restoring power.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?