Schneider Electric ATV12H075M2 1 HP 230VAC Variable Frequency Drive
Controls single-phase 200-240 VAC input to three-phase 0.5-400 Hz output at 1 hp and 4.2 A in a NEMA 1 enclosure
- Overall length7.3
- Product typeBuilding Cable
- 1 HP motor control for industrial automation
- Single-phase 230 VAC input simplifies installation
- Three-phase output enables standard motor use
- Adjustable 0.5 to 400 Hz frequency range
- NEMA 1 enclosure protects drive internals
Schneider Electric ATV12H075M2 VFD
This Schneider Electric ATV12H075M2 variable frequency drive delivers 1 hp maximum output power for single-phase 230 VAC supply networks. It converts the input to three-phase output voltage ranging from 200 to 240 VAC with a 4.2 A current rating. The NEMA 1 enclosure suits indoor industrial installations where basic protection is required.
Altivar single-to-three phase conversion
The drive accepts single-phase AC input at 50 or 60 Hz and produces three-phase output for standard induction motors. Output frequency is adjustable from 0.5 to 400 Hz, allowing wide speed control range. This topology lets users run three-phase motors on single-phase mains without a separate phase converter.
4.2 A output current rating
The 4.2 A maximum output current determines which motor loads the drive can support. Match this figure to the motor nameplate full-load current before purchase. Builders needing higher current capacity must select a larger frame size.
How it compares
Measured against everything we stock in Wire, Cable & Wiring Supplies, at today’s prices. Recalculated every night.
- Price $216.99
- Pricier than about 90% of the 1,610 comparable items (median $25.99).
Specifications
| Product | |
|---|---|
| Brand name | SCHNEIDER ELECTRIC |
| Product type | Building Cable |
Questions about this item
How often should the internal cooling fan of this ATV12H075M2 drive be inspected or replaced?
The drive uses a 4.2 A rated output; fan inspection intervals depend on ambient temperature and duty cycle rather than a fixed schedule.
What thermal limit is reached first when the drive runs continuously at 4.2 A output?
Continuous 4.2 A operation at 200-240 V AC raises heatsink temperature until the built-in overtemperature protection trips.
What is the typical heat dissipation and fan noise level when this drive operates all day at full load?
At 1 hp output the drive loses power as heat inside its NEMA 1 enclosure; the internal fan runs whenever the heatsink temperature rises above its threshold.
More in Wire, Cable & Wiring Supplies
Similar items
Sta-Kon NW14-8 16-14 AWG Non-Insulated Ring Terminal #8 Stud Pack of 100
- NW Series