Schneider Electric GV2P01 Manual Motor Starter 0.16 A 600 V 3 Phase Selector
Manual motor starter with thermal overload protection up to 0.16 A at 600 V AC, three-pole selector operation and screw-clamp terminals rated IP20
- Product typeIndustrial Electrical Controls & Automation
- Thermal overload protection prevents motor damage up to 0.16 A
- Selector switch operator gives clear manual control of three-phase circuits
- IP20 rating and fire-resistant materials suit panel-mount installations
- Screw clamp terminals accept solid or stranded wire without special tools
- Rated 600 V AC at 50/60 Hz for worldwide industrial supply networks
Schneider Electric GV2P01 Manual Motor Starter
The Schneider Electric GV2P01 is a manual motor starter built for three-phase circuits up to 600 V AC. It suits industrial control panels that need local motor on-off control with integrated thermal overload protection for small loads.
Thermal overload upgrade for fractional-horsepower
This starter replaces basic disconnect switches or contactors without overload when protecting motors drawing 0.16 A. The jump is worth it when a single device must provide manual isolation, short-circuit coordination and adjustable thermal trip from 0.1 A to 0.16 A.
DIN-rail mount with screw-clamp terminals
The unit clips onto standard DIN rail and uses screw-clamp terminals for field wiring. IP20 finger-safe housing means no separate enclosure is required, but the selector operator must be accessible on the panel front for manual operation.
How it compares
Measured against everything we stock in Electrical Enclosures & Cabinets, at today’s prices. Recalculated every night.
- Price $190.99
- Pricier than about 86% of the 1,411 comparable items (median $39.99).
Specifications
| Product | |
|---|---|
| Brand name | SQUARE D |
| Product type | Industrial Electrical Controls & Automation |
Questions about this item
What screw-clamp terminal size does the GV2P01 accept?
The starter uses screw-clamp terminals for conductor connection; strip wires to the length shown in the installation guide and tighten to the specified torque.
How is the thermal overload set correctly on this starter?
Rotate the selector dial to match the motor full-load current between 0.1 A and 0.16 A; the common error is leaving the dial at the factory minimum instead of the motor name-plate value.
When should the thermal overload module be replaced?
Replace the module after a trip that cannot be cleared by the reset button or if the starter fails to hold the motor at the 0.16 A setting during routine inspection.