We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Protects motors with adjustable 5.5 to 8 A thermal overload trips for TeSys D contactors up to 38 A
The Schneider Electric LRD12 overload relay pairs with TeSys D contactors to protect motors from overcurrent damage. It covers a trip range of 5.5 to 8 amperes and is calibrated to Class 10A. The unit is certified to IEC, UL, CSA, CCC, EAC, ATEX and Marine standards. It suits maintenance engineers and panel builders who need reliable motor-circuit protection.
Differential thermal sensing reacts to sustained overloads rather than momentary peaks, reducing nuisance trips during normal motor starts. The relay draws negligible control-circuit power and adds no audible noise to the panel. Its calibrated trip curve limits winding heating without affecting the contactor’s switching duty.
The relay mounts directly onto 9 to 38 amp TeSys D contactors, keeping the starter footprint compact. Front-mounted 1NC plus 1NO auxiliary contacts give clear trip indication and simple control-circuit integration. Transparent housing allows visual confirmation of contact status. Buyers needing protection outside the 5.5 to 8 ampere range or a different contact arrangement must select another model.
Measured against everything we stock in AV Accessories & Components, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SCHNEIDER ELECTRIC |
| Product type | Industrial Electrical Controls & Automation |
| Product color | Transparent |
Mount the relay directly onto a 9 A to 38 A TeSys D contactor and set the adjustment dial to the motor full-load current within the 5.5 A to 8 A range; the step often missed is calibrating the dial to the exact motor current before commissioning.
The relay requires no scheduled part replacement; periodically verify the trip setting remains at the correct 5.5 A to 8 A value and inspect terminals for tightness and signs of overheating.
The Class 10A thermal trip curve is the first limit reached; sustained current above the 5.5 A to 8 A setting will cause the relay to open the contactor within the Class 10A time-current characteristic.
More in AV Accessories & Components
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?