Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Provides 0.5 A single-pole branch-circuit protection with D-curve thermal-magnetic trip, 14 kA interrupting at 240 V AC and 60 V DC, DIN-rail mount, screw-clamp terminals for 14–4 AWG wire
The Siemens 5SJ41058HG40 is a single-pole miniature circuit breaker rated at 0.5 A for 240 V AC and 60 V DC branch circuits. It uses a D-curve thermal-magnetic trip and a 14 kA interrupting rating to protect industrial control panels and reverse-feed applications. Builders needing multi-pole or higher-current devices must look elsewhere.
The thermal-magnetic mechanism reacts to sustained overloads and short-circuit currents without external power. In normal operation the breaker dissipates only the losses of its 0.5 A load current and runs silently on the DIN rail. No fan, heatsink or active cooling is required.
Screw-clamp terminals accept conductors from 14 AWG up to 4 AWG, allowing a wide range of field wiring without special tools. The 63 A frame size and UL 489 listing confirm suitability for standard industrial panel builds. No software or configuration accessories are included.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SIEMENS |
Snap the 1-pole housing onto the DIN rail, then secure the screw-clamp terminals on 14 AWG to 4 AWG copper wire; the step often missed is confirming the clamp is fully tightened on each conductor.
The thermal-magnetic mechanism is not serviceable; replace the unit if it trips at or below the 0.5 A rating or after a 14 kA fault event.
The 63 A frame thermal limit governs sustained loading; the D-curve magnetic trip only operates on short-circuit currents well above the 0.5 A rating.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?