We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Three-pole miniature circuit breaker rated 25 A at 240 V AC with a 10 kA interrupting capacity for Siemens panelboards
This Siemens BQ3B025 miniature circuit breaker provides three-pole overcurrent protection at 25 A and 240 V AC. It is built for bolt-on installation in compatible Siemens panelboards using the BQ series frame. The 10 kA interrupting rating at 240 V AC handles typical residential and light commercial fault currents. A toggle actuator gives clear on-off indication for maintenance staff.
Electricians wiring three-phase circuits rated at 25 A in a Siemens BQ panelboard will find this breaker matches the frame size and mounting style. It accepts copper wire from 14 AWG to 6 AWG and aluminium from 12 AWG to 6 AWG. Installers needing a different ampere rating, a different number of poles, or a DIN-rail mount should select another model. The unit is not rated for DC applications.
The decisive specification is the 25 A trip rating within the 125 A BQ frame size. This combination determines whether the breaker fits the panelboard slot and protects the intended conductor size. Verify the panelboard schedule calls for a 25 A three-pole BQ breaker before ordering.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SIEMENS |
The lug terminals accept copper wire from 14 AWG up to 6 AWG and aluminium from 12 AWG up to 6 AWG; a correct initial torque to Siemens specifications is the only required tightening.
The thermal-magnetic trip unit is calibrated to open at 25 A; sustained overloads above that rating will cause the mechanism to trip.
The device is rated for a maximum operating temperature of 104 degrees Fahrenheit, so the enclosure must provide enough ventilation to keep ambient temperature at or below that level.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?