We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Two-pole miniature breaker rated 30 A at 120/240 V AC with plug-in mounting for Siemens EQ load centres, 10 kA interrupting capacity and lug terminals for 14–8 AWG wire
The SIEMENS Q230 is a 30-amp, two-pole miniature circuit breaker designed for 120/240V AC residential panels. It fits Siemens EQ load centers using a plug-in mounting style and accepts wire sizes from 14 AWG to 8 AWG. This standard toggle-actuator device provides branch-circuit protection for compatible electrical installations.
The breaker carries a maximum AIR rating of 10 kA at 120V AC, suitable for typical residential fault-current levels. Its plug-in design allows quick installation without bolt-on hardware. The unit operates within a 125A frame size and has no DC voltage rating, limiting use to AC applications only.
Supplied lug terminals accept solid or stranded copper wire ranging from 14 AWG minimum to 8 AWG maximum. No additional accessories or software are included with this standalone protective device. Builders needing DC-rated protection or a different interrupting capacity must select an alternative model.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | Siemens |
| Product type | Circuit Breakers |
Align the plug-in base with the panel bus, press firmly until it seats fully, then torque the lug terminals to the panel's specified value; the step often missed is verifying the breaker is completely latched onto the bus before tightening wires.
The breaker itself is not serviceable; plan to replace it if it trips repeatedly without overload, shows discoloration at the lugs, or after a fault event that exceeds the 10 kA interrupting rating at 120 V AC.
The 30 A thermal trip curve is the first limit; continuous current above 30 A will cause the breaker to open, and the 8 AWG maximum wire size caps the conductor ampacity that can be safely terminated.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?