We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Connects a single 600 kcmil conductor with tin-plated aluminum body rated for 600 V and 221 °F
The SQUARE D AL400LA is a tin-plated aluminum mechanical lug rated for a single conductor up to 600 kcmil. It accepts stranded copper wire from 1 AWG to 250 kcmil and aluminum conductors within the same range. The connector mounts on a 1/4 inch stud with a hex socket head and operates at up to 600 volts. It suits panel builders and electricians terminating large feeder cables in industrial or commercial equipment.
This lug replaces lower-ampacity connectors when a single 250 kcmil copper or aluminum conductor must be terminated at 600 volts. The jump is justified when the existing lug cannot accommodate the required wire size or the 221 degrees F temperature rating. It is not for applications needing multi-conductor termination, higher voltage classes, or conductors larger than 250 kcmil copper.
The lug handles one conductor at the maximum 250 kcmil copper size with a 600-volt rating and 221 degrees F operating limit. The single-hole mounting on 0.34 inch diameter with 0.88 inch spacing fits standard 1/4 inch stud patterns. It runs out when the design calls for more than one conductor per phase, voltages above 600 V, or wire sizes exceeding the 250 kcmil copper maximum.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SQUARE D |
The lug mounts on a 1/4 in stud with a single 0.34 in diameter hole and 0.88 in hole spacing.
It accepts one aluminum or copper conductor from 1 AWG to 600 kcmil (250 kcmil max for stranded copper); tighten the hex-socket set screw to the manufacturer's specified torque.
Inspect the lug and conductor connection periodically for discoloration, corrosion or overheating signs, especially when operating near the 221 °F temperature limit.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?