Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A bolt-on miniature circuit breaker rated 70 A at 120/240 V AC with a 10 kA interrupting capacity for QO load centres
The SQUARE D QOB270 is a 70 A miniature circuit breaker built for QO series load centres. It protects single-phase 120/240 V AC circuits and carries a 10 kA interrupting rating at that voltage. The two-pole paddle actuator mounts by bolt-on terminals into compatible NQOD panelboards. It suits electricians and maintenance teams fitting or replacing branch-circuit protection in commercial or light-industrial boards.
The device is rated for a minimum operating temperature of 77 °F and a maximum DC voltage of 48 V. Its 100 A frame size and standard breaker type define the thermal-magnetic trip curve for normal loading. No active cooling or fan is present; heat dissipates through the bolt-on lugs and the 3.12 in by 1.5 in by 2.91 in moulded housing during typical operation.
Factory-fitted terminal lugs accept the conductor sizes specified for the 100 A frame, removing the need for separate lug kits. The bolt-on mounting style locks the breaker securely into Square D NQOD panelboards, ensuring positive contact without additional hardware. No software, configuration tools or accessories beyond the lugs are supplied or required for installation.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | SQUARE D |
Align the breaker with the panel bus, press firmly until the bolt-on feet seat, then torque the mounting bolt to spec; the step often missed is confirming the bolt is fully tightened after the breaker clicks in.
No scheduled maintenance is required; replace the breaker if it trips repeatedly without overload, shows discoloration at the lug terminals, or fails to reset cleanly after a fault.
The 70 A thermal trip curve is the first limit; continuous operation above 70 A will cause the breaker to open, while the 10 kA interrupting rating only applies during short-circuit faults.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?