Telemecanique Sensors XY2CH13150H7 Cable Pull Switch 10A 1NO+1NC
Emergency cable pull switch rated 10 A thermal with 1NO+1NC contacts, 50 ft maximum cable span and NEMA 1, 12, 4 enclosure
- Emergency stop up to 50 ft cable span
- 10 A thermal rating handles heavy loads
- Maintained switch stays tripped until reset
- Zamak housing rated NEMA 1, 12, 4
- Left or right cable entry fits layout
Emergency Cable Pull Switch
The Telemecanique Sensors XY2CH13150H7 is a maintained emergency stop device rated for 10 A thermal current. It provides one normally open and one normally closed contact for safety circuits. The switch suits machinery where a single cable spans up to 50 ft.
Zamak Housing with NPT Entry
A Zamak case carries NEMA 1, 12 and 4 ratings for indoor and sheltered outdoor use. Wiring enters through a 1/2 in NPT port on the left or right side. Push-button reset and a 4.5 lb operating force allow deliberate actuation without nuisance trips.
Replaces Worn or Unrated Pull Switches
The unit upgrades older switches that lack NEMA 4 protection or the 3 A at 240 V AC and 0.27 A at 250 V DC ratings. It is not suited for applications needing dual-cable operation or an integrated indicator light.
How it compares
Measured against everything we stock in Contactors, Relays & Motor Starters, at today’s prices. Recalculated every night.
- Price $304.99
- Pricier than about 92% of the 1,098 comparable items (median $61.99).
Specifications
| Product | |
|---|---|
| Brand name | TELEMECANIQUE SENSORS |
Questions about this item
What AC voltage and current does the 1NO+1NC contact block actually switch?
The contacts are rated for 3 A at 240 V AC and 0.27 A at 250 V DC, with a thermal rating of 10 A.
What mounting space and cable entry does the Zamak housing require?
The body measures 7.76 in long, 2.68 in wide and 1.57 in deep, with a 1/2 in NPT wiring entry on the left or right side.
How is the switch reset after an emergency pull, and what is the common mistake?
After the cable is tensioned, press the blue push-button reset; the error is forgetting to re-tension the cable before resetting.
More in Contactors, Relays & Motor Starters
Similar items
Intermatic PE153 Digital Timer 24 hr 3 SPST 120/240V contactor
TORK nsi DWZ200B Electronic Timer 365 Day SPDT 20A 120-277VAC
- IEC Delay Timers
Dayton 5UKF7 Capacitor-Start Motor 1 hp 115/208-230V AC
- Closed Base
Acuity Sensor Switch NCM ADCX RJB daylight photosensor 12 24VDC
Dayton 30PT51 1/4 hp 115/230V AC Capacitor-Start/Run Motor
- Closed Base