CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Rack-mountable 3U UPS delivers 2100 watts from 3000 VA at 208 V with 33.9 minutes half-load runtime and SmartSlot management
The APC SURTD3000XLT delivers 3000 VA and 2100 watts of continuous double-conversion power at 208 volts. It fits a standard 3U rack space and provides four locking outlets — two NEMA L6-20R and two NEMA L6-30R — for critical server and networking loads. Automatic internal bypass maintains utility power to connected equipment if the UPS experiences an overload or fault.
At full 2100-watt load the unit runs for 14.1 minutes on battery; at half load (1050 watts) runtime extends to 33.9 minutes. The battery recharges to usable capacity in 2.50 hours after a discharge event. Input voltage tolerance spans 160 to 280 volts at 50 or 60 hertz with auto-sensing, so the UPS stays online through prolonged brownouts without draining the battery.
This model replaces shorter-run 3U units when longer battery autonomy is required for graceful shutdown or generator start sequences. It is not suited for installations needing 120-volt output, higher VA ratings, or additional outlet count beyond the four locking receptacles provided. SmartSlot and RJ-45 serial ports enable remote management integration where the existing infrastructure supports those interfaces.
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Brand name | APC |
| Model name | SURTD3000XLT |
| Ports & slots | |
| Communication ports | RJ-45 Serial, SmartSlot |
| Power | |
| AC input voltage | 160–280 V |
| Input line frequency | 50/60 Hz +/- 5 Hz (auto sensing) |
| Volt-ampere rating | 3000 VA |
| Power rating | 2100 W |
| Voltage output | 208 V |
| Power outlets | 4 |
| Runtime on battery | Half Load: 33.9 minutes (1050 W) Full Load: 14.1 minutes (2100 W) |
| Battery charge time | 2.5 h |
| Alerts | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
| Surge protection rating | 480 Joules |
| Size & build | |
| Rack mounting | 3U |
| Product dimensions | 17 in × 5.1 in × 26 in |
| Product weight | 120 lb (54.4 kg) |
| Shipping weight | 66.22 kg |
| Package size | 980 × 603 × 347 mm |
| Environment & compliance | |
| Regulatory approvals | CSA,FCC Part 15 Class A,UL 1778 |
| Software | |
| Control software | YES |
The unit uses internal fans for cooling; expect noticeable airflow and audible fan noise in a quiet room, and plan for the 2100 W full-load heat output when sizing rack ventilation.
The UPS requires a 208 V single-phase supply within the 160 – 280 V range on a circuit rated for at least 30 A, terminated with a compatible locking plug that matches your facility wiring.
Yes — the rear panel provides two NEMA L6-20R and two NEMA L6-30R receptacles, so cords with those connectors plug in directly without adapters.
More in Uninterruptible Power Supplies (UPS)
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?