Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A pack of five 6 A glass time-delay fuses rated 125 V AC with a 10 kA interrupt rating
This Bussmann GMC-6-R glass fuse is rated at 6 A and 125 V AC with a 10 kA interrupt rating. The time-delay, cylindrical body suits equipment that experiences brief inrush currents. Each pack contains five fuses for spares or multi-point protection. It fits standard 5 mm × 20 mm fuse blocks such as the HTB series.
The glass body allows visual confirmation of the element status after a fault. Time-delay operation prevents nuisance opening during temporary overloads while still interrupting short-circuit current up to 10 kA at 125 V AC. The non-rejection design accepts standard clip-type holders without a keyed slot. No active cooling or moving parts are involved, so operation is silent.
The pack supplies five identical fuses, reducing downtime when a replacement is needed. Equivalent series references include Littelfuse 239 and Mersen GSC for easy sourcing alternatives. Certifications cover CE, CSA Class 1422-01 and UL 248-14 Guide JDYX, confirming compliance for North American installations. Buyers who need a higher voltage rating or a different amperage must select another part number.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
Insert the 20 mm x 5 mm cylindrical glass body into a compatible HTB fuse block until the metal caps seat fully; the step often missed is confirming the 10 kA interrupt rating at 125 V AC matches the circuit's prospective fault current.
As a single-element, time-delay glass fuse it is not serviceable; after any over-current event that opens the element, replace the entire fuse with another 6 A, 125 V AC, 10 kA rated unit from the 5-pack.
The 6 A continuous current rating is the first limit; operating above 6 A will cause the time-delay element to melt, while the 10 kA interrupt rating only applies during short-circuit faults.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?