Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 40 A fast-acting cylindrical fuse rated 600 V AC and 600 V DC for photovoltaic line protection
The Bussmann PVS-R-40 is a fast-acting cylindrical fuse rated at 40 amps for 600 volts AC and DC. It carries a Class RK5 rejection design and meets UL 2579 photovoltaic standards. The fuse is built for solar array string protection where reliable overcurrent interruption is required. It suits installers and system integrators working on commercial or residential PV installations.
The single-element construction delivers fast-acting response under continuous fault conditions rather than only during momentary surges. Interrupt ratings reach 200 kiloamps at 600 volts AC and 20 kiloamps at 600 volts DC, ensuring safe circuit isolation during prolonged overcurrent events. The fiberglass body maintains structural integrity through repeated thermal cycling. Performance aligns with CSA Component Certified C 22.2 and UL Std. 248-12 requirements.
The 5-1/2 inch length by 1-1/16 inch diameter fiberglass body fits standard RK5 rejection fuse blocks, preventing incorrect fuse substitution. Non-indicating design means visual status checks are not possible, so maintenance relies on scheduled electrical testing. UL Listed and Guide JFGA classification confirm compliance for photovoltaic disconnect applications. The rejection feature ensures only correctly rated fuses can be installed in compatible holders.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | EATON BUSSMANN |
A fuse of this rating dissipates only a few watts at full load, so temperature rise inside a properly ventilated combiner box is minimal and requires no active cooling.
It must be mounted in a 600 V Class RK5 rejection fuse block or PV-rated disconnect that accepts a 5-1/2 in × 1-1/16 in cylindrical body.
Yes, provided the existing holder is Class RK5 rejection type and the system voltage does not exceed 600 V AC or DC.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?