Bussmann JM60030-3PR line protection 30A 600V 3 poles 3.3 in
- Circuit Breakers
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
IEC miniature circuit breaker rated 1 A, single-pole, C-curve, 277 V AC / 48 V DC, 10 kA interrupting, DIN-rail mount, thermal-magnetic trip, UL 489 listed, 12-28 AWG lug terminals
The Dayton 33V886 is a single-pole IEC miniature circuit breaker rated at 1 A with a C-curve thermal-magnetic trip. It mounts on a standard DIN rail and accepts wire from 28 AWG to 12 AWG via lug terminals. The unit carries UL 489 listing for the US and Canada and CE marking for European compliance.
The thermal element responds to prolonged over-currents while the magnetic element clears short circuits up to 10 kA at 277 V AC. Rated for 277 V AC and 48 V DC, it maintains protection across the full temperature range without nuisance tripping on normal inrush. The 32 A frame size ensures consistent performance under continuous load.
This breaker replaces legacy 1 A toggle devices that lack UL 489 certification or a 10 kA interrupting rating. The jump is worthwhile when a panel requires documented short-circuit withstand at 277 V AC or when a project demands CE-marked components for export. It is not suited for applications needing multi-pole ganged switching or higher frame ratings.
Measured against everything we stock in Breakers & Circuit Protection, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | DAYTON |
At 1 A the thermal element carries rated current without nuisance tripping; the magnetic coil only operates on fault currents up to 10 kA, so steady-state dissipation stays low and the unit remains cool during all-day operation.
The breaker clips onto standard DIN rail and uses integral lug terminals that accept solid or stranded copper from 12 AWG down to 28 AWG; no separate connectors or bus bars are required.
The C-curve magnetic trip (5-10 × In) provides selective discrimination against the larger 32 A frame upstream, so a downstream fault clears at the 1 A device first while the feeder remains closed.
More in Breakers & Circuit Protection
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?