We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Three-phase open drip-proof motor delivers 3 hp at 3445 rpm with 85.5 % nominal efficiency, 230/460 V AC dual voltage and 1.15 service factor in a rigid-base 182/4 steel frame
This Dayton 36VE99 is a three-phase general purpose motor rated at 3 hp. It operates on 230/460V AC at 60 Hz with a nameplate speed of 3445 RPM. The open drip-proof enclosure and steel frame suit industrial environments where ventilation is adequate. Full-load current is 7.8 amps at 230 volts and 3.9 amps at 460 volts.
This motor suits pumps, fans, compressors and conveyors that run continuously on three-phase supply. The 1.15 service factor and Class F insulation handle sustained loads at up to 40 °C ambient. Buyers who need variable-speed control, integrated thermal protection or a totally enclosed enclosure should look at other designs. Single-phase installations cannot use this motor.
Confirm the site provides three-phase power at either 230 V or 460 V and that the starter or contactor is rated for the corresponding full-load amps. The rigid base matches NEMA 182/4 frame dimensions; check bolt pattern and shaft height against the driven equipment. A shaft key is included for coupling alignment. Ensure rotation direction (CW/CCW) matches the application before wiring.
Measured against everything we stock in General Hardware & Accessories, at today’s prices. Recalculated every night.
| Product | |
|---|---|
| Brand name | DAYTON |
| Product type | Motors |
The motor is rated for 230/460 V AC at 60 Hz, so your plant must supply either 230 V or 460 V three-phase power at 60 Hz.
The motor uses a standard NEMA 182/4 frame with a rigid steel base; verify your equipment’s bolt-hole pattern against NEMA 182/4 dimensions before installation.
Measure the line current at full load — it should read approximately 7.8 A at 230 V or 3.9 A at 460 V — and check that the shaft speed is near the 3445 RPM nameplate value.
More in General Hardware & Accessories
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?