Eaton 9PX6K 6000VA 5400W 208V UPS
Double-conversion UPS delivers 6000 VA and 5400 W at 208 V with four outlets and hot-swappable batteries
- AC input voltageFull load: 176-276 V, Derating: 100-276 V
- Input line frequency50/60 Hz
- Power input1 x Terminal block with L6-30P
- Volt-ampere rating6000 VA
- Power rating5400 W
- Voltage output208 V default (200/208/220/230/240 V)
VA 6000 VA
- 5000 VA$3,774.99
- 6000 VA$4,968.99
- Online double-conversion topology delivers clean 208 V power
- 6000 VA 5400 W capacity supports dense IT loads
- 40 % less energy used cuts operating cost
- Hot-swappable batteries enable runtime extension without shutdown
- 3U rack/tower form factor fits standard cabinets
6 kVA double-conversion UPS for IT rooms
The Eaton 9PX6K delivers 6000 VA and 5400 W of online power protection in a 3U rack or tower form factor. It targets small to medium data centres and infrastructure managers who need efficient, continuous backup for critical loads.
Input window 100–276 V
The unit accepts 50 or 60 Hz and connects via a terminal block with L6-30P plug. Output voltage defaults to 208 V and is selectable among 200, 208, 220, 230 and 240 V. Four outlets provide two L6-20R, two L6-30R and a hardwired option. Surge protection meets IEEE ANSI C62.41 Cat B2.
Runtime 0.13 hour at half load
Hot-swappable lead-acid batteries support extended run configurations. Management uses RS-232 over RJ45, USB HID and an included SNMP network card. The UPS suits installations that can accommodate 106 lb weight and 5.1 by 17.3 by 28.4 inch dimensions. It does not suit buyers who need longer battery autonomy without extra modules.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $4,968.99
- Pricier than about 90% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | EATON |
| Model name | 9PX6K |
| Ports & slots | |
| Communication ports | RS-232 (RJ45) ports; USB port as standard (HID) |
| Power | |
| AC input voltage | Full load: 176-276 V, Derating: 100-276 V |
| Input line frequency | 50/60 Hz |
| Power input | 1 x Terminal block with L6-30P |
| Volt-ampere rating | 6000 VA |
| Power rating | 5400 W |
| Voltage output | 208 V default (200/208/220/230/240 V) |
| Power outlets | 4 |
| Runtime on battery | 0.13 Hour |
| Size & build | |
| Rack mounting | Yes |
| Product dimensions | 5.1 in × 17.3 in × 28.4 in (H × W × D) |
| Product weight | 106 lb (48.1 kg) |
| Shipping weight | 57.61 kg |
| Package size | 965 × 721 × 311 mm |
| Environment & compliance | |
| Regulatory approvals | CE / cULus / NOM |
| Software | |
| Control software | YES |
| More details | |
| Surge protection | IEEE ANSI C62.41 Cat B2 |
Other versions of this model
1 more in the same range
Questions about this item
Should I pick the L6-20R or L6-30R outlets for my servers?
Use the two L6-30R outlets for loads up to 30 A each, and the two L6-20R outlets for loads up to 20 A each. Total output must not exceed 5400 W.
What does the 5400 W rating mean when the UPS is running my equipment?
It is the maximum real power the unit can supply continuously. At 5.40 kW full load the battery lasts 0.05 hour; at 2.70 kW half load it lasts 0.13 hour.
What does the RS-232 RJ45 and USB HID interface actually let me do?
The USB HID port gives native OS monitoring without extra drivers. The RS-232 RJ45 port connects to the included network card for SNMP management.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
Vertiv GXT5-5000MVRT4UXLN UPS 5kVA 5kW 208V 120V
- 176 V AC - 280 V AC
- 120 V AC, 180 V AC,…
CyberPower OL6KRTHD 6000VA/6000W UPS 200-240V 2U Rack/Tower
- 200 V AC - 240 V AC
- 200 V AC, 208 V AC,…
Tripp Lite OMNI900LCD UPS 900VA 475W 120V Tower LCD USB
- 120 V AC
- 5-15P