CyberPower CP1350PFCLCD 1350VA 880W 120V 12 Outlet UPS
- 78–142 V
- 57–63 Hz
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Scalable 20 kVA rack/tower UPS with hardwired input and multiple NEMA outlets for 208-240 V environments
The Eaton 9PXM12S20K-PD is a 20 kVA battery backup that scales to 20 kVA in an N+1 redundant configuration. It accepts hardwired 208-240 V AC input and fits a 21U rack or tower footprint. The unit targets data-centre and critical-infrastructure operators who need high-density power protection with room for growth.
The 690 lb chassis uses forced-air cooling across a 34.5 in depth and 36.5 in height to manage heat at full load. Fan speed ramps with load percentage, so acoustic output rises only when the UPS is delivering near-rated power. Double-conversion topology keeps input current clean while the battery system carries the load during outages.
Eight NEMA 5-20R, two L6-20R, two L6-30R and two L14-30R receptacles let you connect servers, networking gear and peripheral strips without adapter cables. FCC, ICES-003 and TAA markings simplify deployment in regulated environments. The hardwired input requires professional installation, so the unit is not suited for plug-and-play desktop use.
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Brand name | EATON |
| Model name | 9PXM12S20K-PD |
| Power | |
| AC input voltage | 208 V AC - 240 V AC |
| Power outlets | 2 x NEMA L14-30R 2 x NEMA L6-20R 2 x NEMA L6-30R 8 x NEMA 5-20R |
| Size & build | |
| Shipping weight | 312.98 kg |
| Package size | 927 × 927 × 445 mm |
Have a qualified electrician connect the supply to the unit's hardwired input terminals; the step often missed is verifying the branch-circuit breaker matches the 20 kVA rating before energising.
It uses Eaton 9PXM battery modules; the scalable 12-slot frame requires up to 12 modules for full 20 kVA N+1 redundancy.
The outlet current limits appear first: each L6-30R is rated 30 A, each L6-20R 20 A, and each 5-20R 20 A, so total connected load must stay within those per-receptacle ratings.
More in Uninterruptible Power Supplies (UPS)
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.